Sub-Zero SO30-2B/G-TH SO30CE/B/TH, SO30-2U/S-TH SO30TE/S/TH, DO30-2F/S-TH NA Planning Information

Models: SO30-2B/G-TH SO30CE/B/TH DO30-2B/G-TH DO30CE/B/TH DO30-2F/S-PH DO30PE/S/PH DO30-2U/S-TH DO30TE/S/TH SO30-2F/S-PH SO30PE/S/PH SO30-2F/S-TH NA DO30-2F/S-TH NA SO30-2U/S-TH SO30TE/S/TH

1 106
Download 106 pages 48.52 Kb
Page 63
Image 63
When installing against a combustible surface, a minimum 10" (254) riser is required for a 36" dual fuel range with charbroiler or griddle and all 48" and 60" models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.

WOLF DUAL FUEL RANGES

Planning Information

When installing against a combustible surface, a minimum 10" (254) riser is required for a 36" dual fuel range with charbroiler or griddle and all 48" and 60" models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.

It is recommended that you use a Wolf pro ventilation hood or hood liner with the dual fuel range. If the range is to be installed without ventilation, a 36" (914) minimum clearance, 44" (1118) for charbroiler, from countertop to combustible materials above the range is required. Refer to page 92 for pro ventilation.

BURNER RATING—Btu (kW)

SURFACE BURNER

SIMMER

HIGH

(3 or 5) Large

950 (.3)

15,000

(4.4)

(1) Small

325 (.1)

9,200

(2.7)

FEATURE

NATURAL

 

LP

Charbroiler

16,000 (4.7)

16,000

(4.7)

Griddle

15,000 (4.4)

13,000

(3.8)

Double Griddle

30,000 (8.8)

26,000

(7.6)

French Top

15,000 (4.4)

15,000

(4.4)

ELECTRICAL

Wolf dual fuel ranges have a terminal block that allows for a 3-wire or 4-wire installation.

ELECTRICAL REQUIREMENTS

SINGLE OVEN RANGE

 

Electrical Supply

grounded, 240/208 VAC, 60 Hz

Service

30 amp dedicated circuit

Total Amps

21

DOUBLE OVEN RANGE

 

Electrical Supply

grounded, 240/208 VAC, 60 Hz

Service

50 amp dedicated circuit

Total Amps

42.5

GAS SUPPLY

A gas supply line of 3/4" (19) rigid pipe must be provided to the range. If local codes permit, a certified, 3' (.9 m) long,

1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the units 1/2" NPT female inlet to the gas supply line.

Wolf natural gas ranges will function up to 10,250' (3124 m) in altitude without adjustment and LP gas ranges will func- tion up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.

GAS SUPPLY REQUIREMENTS

NATURAL GAS

 

Gas Supply Pressure

5" (12.5 mb) WC

Min Line Pressure

7" (17.5 mb) WC

Max Pressure to Regulator

14" (34.9 mb) WC, .5 psi (3.5 kPa)

LP GAS

 

Gas Supply Pressure

10" (25 mb) WC

Min Line Pressure

11" (27.4 mb) WC

Max Pressure to Regulator

14" (34.9 mb) WC, .5 psi (3.5 kPa)

wolfappliance.com 63

OVENS / WARMING DRAWERS

COOKTOPS

RANGES / RANGETOPS

OUTDOOR GRILLS

VENTILATION

Page 63