Sub-Zero SO30-2F/S-TH NA Downdraft, Wolf Cooktop Ventilation, Installation With Cooktop, 81/4

Models: SO30-2B/G-TH SO30CE/B/TH DO30-2B/G-TH DO30CE/B/TH DO30-2F/S-PH DO30PE/S/PH DO30-2U/S-TH DO30TE/S/TH SO30-2F/S-PH SO30PE/S/PH SO30-2F/S-TH NA DO30-2F/S-TH NA SO30-2U/S-TH SO30TE/S/TH

1 106
Download 106 pages 48.52 Kb
Page 90
Image 90
INSTALLATION WITH COOKTOP

WOLF COOKTOP VENTILATION

Downdraft

INSTALLATION WITH COOKTOP

W

DOWNDRAFT

CUT-OUT WIDTH

211/16" (68)

E

81/4" (210)*

COOKTOP CUT-OUT

TOP VIEW

81/4"

211/4"

(210)*

(540)

211/4" 233/8"

(540)(594)

E

SIDE VIEW

FRONT VIEW

*6" (152) back from countertop cut-out when internal blower is rear mounted.

NOTE: Internal blower 6" (152) round, side, rear or bottom discharge. In-line and remote blower 10" (254) round, rear discharge. Centerline indicates center of downdraft cut-out.

CUT-OUT WIDTH

MODEL

W

DD30

271/2" (699)

DD36

331/2" (851)

DD45

391/2" (1003)

90 Wolf Customer Care 800.222.7820