15
HP LaserJet 9000
HP Part # C4583X
OEM Stated Yield: 30,000
Like the HP-4100, the 9000 cartridge also uses a
chip. The chip in the 9000 is the same as the 4100 in
that they only monitor usage not page counts. Each
chip also has its own serial number which in effect
gives the cartridge a serial number. After the OEM
toner has been used up, the “toner low reached” code
will be set to YES on the cartridge chip. Even after
the cartridge is refilled, the printer display will still
show “Toner Low” for the supplies status section of
the menu. The main display will then show “Non HP
Toner cartridge”. If the chip is removed, the toner
low sensors will be disabled, and will not work again
until a new HP cartridge is installed. New
replacement chips are available.
HP LaserJet M3027/3035/P3005
HP Part # Q7551A, Q7551X
OEM Stated Yield: 6,500 Q7551A, 13,000
Q7551X
The Q7551A/X cartridges use the older 2nd
generation of chips. They are identical in looks to
the 4200/4300 series. As these machines had just
been released at the time of this writing, no
information on the chip function is available. Check
with your supplier for more information.
HP LaserJet M5035
HP Part # Q7570A
OEM Stated Yield: 15,000
The M5035 uses the latest or 3rd generation chip.
They are very small, and the code is all new. They
are identical in looks to the 5200 series. As these
machines had just been released at the time of this
writing, no information on the chip function or reset
if needed is available. Check with your supplier for
more information.
HP LaserJet P2015
HP Part # Q7553X
OEM Stated Yield: 15,000
The Q7553X cartridges use the older 2nd generation
of chips. They are identical in looks to the
4200/4300 series. The code is all new but as these
machines had just been released at the time of this
writing, no information on the chip function or reset
if needed is available. Check with your supplier for
more information.
Kyocera F-1000 OPC
Kyocera OPC Part # DK-3
OEM Stated Yield: 10,000
There is a small black fuse located on the board
inside the cartridge. This fuse must be replaced each
cycle by un-soldering the old and soldering in the
new. This fuse is a special 250mA one that should
be purchased from your supplier. The same fuse is
used in the F-3010 OPC Cartridge.