OEM Stated Yield: 20,000 (All)

These cartridges do not use any reset procedures at all. According to the Sharp manual, they should be replaced when the copy quality deteriorates. No codes will show on the display to change the cartridge. NOTE: None of these cartridges are interchangeable, they all are slightly different.

Sharp AL-800

Sharp Part # AL-80DR

OEM Stated Yield: 20,000

Open the front cover, and turn the power on. While pressing and holding both the “Exposure mode” and the “Clear key”, close the front cover. Continue to hold these keys for 5 seconds, until the drum light goes out.

Sharp JX-9600 Toner Cartridge

Sharp Cartridge Part # JX-96ND

OEM Stated Yield: 15,000

This cartridge needs to have the fuse replaced each cycle. The replacement fuses are physically different from the OEM but work the same. The fuses for this cartridge are a special, very fast acting, type and must be ordered from your supplier. The replacement fuse must be inserted across the two screws as shown. We have found it best to use solid telephone wire and wire wrap around the fuse posts. Soldering wires to the fuse can cause the

fuse to blow if too much heat is used.

Xerox XE60/80

Xerox Cartridge Part # 13R553

OEM Stated Yield: 18,000

With the power on, open the front door. Hold the “Copy Contrast” button while closing the front door, continue holding the button down for 3 seconds, then release.

Sharp JX-9500 OPC/Toner

Sharp Cartridge Part # JX-95DR

OEM Stated Yield: 50,000 OPC, 25,000 Toner

There is a glass fuse located under a clip on the top of the cartridge. Replace the fuse each cycle. The fuse is a 250V, 80mA, 5x20mm fast acting glass type. The toner waste bottle also uses a fuse- a 250V, 50Ma 5x20mm fast acting glass type.

Sharp JX-9600 OPC Cartridge

With the exception of starter cartridges, these cartridges have a small board located on the end of the cartridge. The small surface mount micro fuse (125mA) must be replaced each cycle. If you have a starter cartridge the machine must be reset through the menu. (Starter cartridges do not have a fuse board.) Almost all of the machines have a different, and complicated reset procedure. Two of the most popular machines are listed below. Other machines probably also have a similar type of reset procedure, but we have not been able to confirm them.

Sharp JX-9600

Sharp OPC Cartridge Part # JX96DR

OEM Stated Yield: 30,000 Turn the printer off.