Sun Microsystems 2.0 manual Using the ILOM CLI, To Verify NEM Status, Using the ILOM Web Interface

Models: 2.0

1 63
Download 63 pages 24.81 Kb
Page 28
Image 28

You can use the ILOM web interface or ILOM CLI to verify

Using the ILOM Web Interface

1.Log in to the ILOM web interface using the IP address of the active Chassis Monitoring Module.

The first page of the ILOM web interface is displayed.

2.In the left navigation pane, select CMM (Chassis Monitoring Module). The ILOM Version Information page is displayed.

3.Select the System Information tab, and then the Components tab. The Component Management page is displayed.

4.Verify that the selected NEM has returned the expected feedback. See “To Verify NEM Status” on page 16.

Using the ILOM CLI

1.Log in to the ILOM CLI of the active Chassis Monitoring Module.

2.For a list of components in your system, type: show /CH

3.To verify that the NEM Ready to Remove status has changed to Not Ready, type: show /CH/component prepare_to_remove_status

The system returns:

prepare_to_remove_status = Not Ready

4.Verify that the selected NEM has returned the expected feedback. See “To Verify NEM Status” on page 16.

To Verify NEM Status

See TABLE 2-3for a description of the LED states for the NEM. See FIGURE 2-5for the location of the LEDs, Attention button, and Locator button.

1.Check the following LEDs to verify that the NEM is ready for a hot-plug insertion.

16 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007

Page 28
Image 28
Sun Microsystems 2.0 manual Using the ILOM CLI, To Verify NEM Status, Using the ILOM Web Interface