Sunrise Global 13-05024, 13-05020 Installation Instructions, Installation of the indoor unit

Models: 13-05020 13-05024

1 24
Download 24 pages 28.37 Kb
Page 20
Image 20
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation of the indoor unit

1.When routing the piping and wiring from the left or right side of the indoor unit, cut off the tai- lings from the chassis in neces- sary (shown in Fig.4, (a), (b) (c)).

(1)Cut off the tailings 1 when routing the wiring only.

(2)Cut off the tailings 1 and tai- lings 2 (or tailings 1, tailings 2 and tailings 3) when routing both the wiring and piping. 1, 2 and 3 in Fig. 4 are the recommended piping.

2.Wrap the piping and wiring and pull them through the cut-off- tailings hole (Shown in Fig. 5).

3.Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough. (Shown in Fig. 6).

4.The height of the installed loca- tion should be 2 m (78-3/4”) or more from the floor.

Right piping

Right rear piping

Tailings 3

Tailings 2

Tailings 1

Installation of the indoor unitInstallation of the outdoor unitLeft piping

Left rear piping

Fig.4

Wrapping tape

Connection pipes

Power connection cord

Drainage hose

Fig.5Fig.6

Installation of the outdoor unit

Install the connection pipe

1.Align the center of the piping flare with the relevant valve.

2.Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to Fig.7.

NOTE: Exceeding tightening torque will damage the flare surface.

Tightening torque table

Torque wrench

Spanner

Flare Joint nut

Fig.7

Hex nut diameter (mm)

Tightening torque (N.m)

ø 6

15 ~ 20

ø 12

50 ~ 55

 

19

Page 20