Note on Torque Setting: A torque setting is the optimum tightening which should be made on a particular fastener. A torque wrench which measures in./lbs. Should be used when tightening fasteners on Quickie wheelchairs. Unless otherwise noted, use a torque setting of 120 in./lbs.When setting up this wheelchair.

A. BATTERY REMOVAL AND

INSTALLATION

To remove the batteries for transporting or servicing:

1.Remove Batteries

a)Unplug the battery connectors located on the controller plate for both battery boxes.

b)Push battery cables under battery tray lever (A).

c)Lift tray lever (A) up.

d)Fold tailgate (B) down.

e)Slide batteries under motors, away from chair.

f)Lift up batteries by lifting up on battery lifting straps (C ).

Batteries my weigh up to 55 lbs.Care must be taken to avoid injury when lifting.

2.Installing Batteries

a)Lift tray lever (A) up, lower tailgate (B).

b)Slide batteries onto tailgate. Cables should be positioned to the rear of batteries.

c)Slide batteries all the way forward on battery tray.

d)Lift up on tailgate.

e)Pull tray lever down.

f)Plug battery cables into connectors.