8 - 4 DS6707 Digital Imager Scanner Product Reference Guide

RS-232 Host Parameters
Various RS-232 hosts are set up with their own parameter default settings (Table 8-2). Selecting standard, ICL,
Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults
listed below.
Table 8-2
Terminal Specific RS-232
Parameter ICL Fujitsu Wincor-Nixdorf
Mode A
Wincor-Nixdorf
Mode
B/OPOS/JPOS Olivetti Omron
Transmit Code ID Yes Yes Ye s Yes Ye s Yes
Data Transmission
Format Data/Suffix Data/Suffix Data/Suffix Data/Suffix Prefix/Data/
Suffix Data/Suffix
Suffix CR (1013) CR (1013) CR (1013) CR (1013) ETX (1002) CR (1013)
Baud Rate 9600 9600 9600 9600 9600 9600
Parity Even None Odd Odd Even None
Hardware
Handshaking RTS/CTS
Option 3 None RTS/CTS
Option 3 RTS/CTS
Option 3 None None
Software
Handshaking None None None None Ack/Nak None
Serial Response
Time-out 9.9 Sec. 2 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec.
Stop Bit Select One One One One One One
ASCII Format 8-Bit 8-Bit 8-Bit 8-Bit 7-Bit 8-Bit
Beep On <BEL> Disable Disable Disable Disable Disable Disable
RTS Line State High Low Low Low = No data
to send Low High
Prefix None None None None STX (1003) None
* In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
**If Nixdorf Mode B is scanned without the digital imager scanner connected to the proper host, it may appear unable
to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the digital imager
scanner.