4 - 2 DS6707 Digital Imager Scanner Product Reference Guide

Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high,
scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-5. The digital imager
scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning
several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences and Miscellaneous Options - Parameter Defaults
Table 4-4 lists defaults for user preferences parameters. There are two ways to change the default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, scan the *Set All Defaults bar code on page 4-4.
Download data through the device’s serial port using SSI. Hexadecimal parameter numbers are shown in
this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying
bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for
changing parameters using this method.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies,
and miscellaneous default parameters.
Table 4-4
User Preferences Parameter Defaults
Parameter Parameter
Number Default Page
Number
User Preferences
Set Default Parameter All Defaults 4-4
Parameter Scanning ECh Enable 4-4
Beeper Tone 91h Medium 4-5
Beeper Volume 8Ch High 4-6
Power Mode 80h Continuous On 4-6
Time Delay to Low Power Mode 92h 1 Minute 4-7
Trigger Mode 8Ah Auto Aim 4-8
Picklist Mode F0h 92h Disabled Always 4-9
Decode Session Timeout 88h 9.9 Sec 4-10