10 - 10 DS6707 Digital Imager Scanner Product Reference Guide
Decode UPC/EAN/JAN Supplementals (continued)
UPC/EAN/JAN Supplemental Redundancy
Parameter # 50h
With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a
symbol without supplementals is decoded before transmission. The range is from two to thirty times. Five or
above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplementals, and
the autodiscriminate option is selected. The default is set at 10.
Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar codes in Appendix D,
Numeric Bar Codes. Single digit numbers must have a leading zero. To correct an error or change a selection,
scan Cancel on page D-2.
Enable 378/379 Supplemental Mode
(04h)
Enable 978 Supplemental Mode
(05h)
Enable Smart Supplemental Mode
(03h)
UPC/EAN/JAN Supplemental Redundancy