5 - 6 MC70 User Guide

Simultan eously charges up to four EDAs.

Charging

Insert the EDA into a slot to begin charging.
Figure 5-5
EDA Battery Charging
Battery Charging Indicators
The EDA’s charg e LED shows the status of the battery charging in the EDA. See Table 1-2 on page 1-7 for
charging status indications.
The st andard battery fully cha rges in appr oximately fo ur ho urs and the exten ded cap acity battery fully charge s
in approximately ei ght hours.
Charging Temperature
Charge batteries in temperatures from 0oC to 40oC (32°F to 104°F). Note that at temperatures above 35oC,
charging is intelligently controlled by the EDA and the charging accessory in order to ensure safe operation
and optimize long-term battery life.
To accomplish this, for small periods of time, the EDA or acce sso r y alte rn at ely ena bles an d dis ab les bat te ry
charging to keep the battery at acceptable temperatures. The EDA or accessory indicates when charging is
disabled due to abno rmal temperatures via its LED. See Table 1-2 on page 1-7.
NOTE Use only a Symbol-approved power supply output rated 12 Vdc and minimum 9A. The
power supply is certified to EN60950 with SELV outputs. Use of an alternative power supply will
inv alidate any appro val given to this device and may be dangerous.
HINWEIS Benutzen Sie nur eine v on Symbol Technologies genehmigte Strom versorgung mit einer
Ausgangsleistung von 12 V (Gleichstrom) und mindestens 9A. Die Stromversorgung ist nach
EN60950 für die Verwendung in SELV-Stromkreisen zertifiziert. Bei Verwendung eines anderen
Netzteils werden alle für das Gerät gewährten Genehmigungen außer Kraft gesetzt, und der
Betrieb kann gefährlich sein.