OPERATION MANUAL
SPECIFICATIONS
FUNCTIONAL SPECIFICATIONS
Service: | Clean, dry, |
| tin u ous Purge op tion. Con sult fac tory . |
Pres sure Ranges: | Stan dard Pres sure Ranges: | |
| Range 1: | 0 to 0.10” (0 TO 2.54mm) W.C. |
| Range 2: | 0 to 0.25” (0 to 6.35mm) W.C. |
| Range 3: 0 to 1.0” (0 to 25.4mm) W.C. |
Range 4: 0 to 4.0” (0 to 101.6mm) W.C.
Range 5: 0 to 16.0” (0 to 406.4mm) W.C.
Range 6: 0 to 50.0” (0 to 1270.0mm) W.C.
Out put Sig nals: | Analog: | |
| ble to Dif fer en tial Pres sure or Flow Parameters. Ex ter nal in puts or pro grammed con stants | |
| for tem per a ture and ab so lute pres sure along with con stants for Ef fec tive Area and Stan dard | |
| Den sity, are nec es sary for a true flow mea sure ment. | |
| Op tional Dig i tal: One (1) op tional dig i tal (open col lec tor) out put avail able. Ac ti va tion pro- | |
| gram ma ble by end user. |
|
Communications: | Op tional: digitalHART® Com mu ni ca tions mod ule. See Sec tion 13, page 23 for HART® com- | |
| municationinformation. |
|
Alarms: | Programmablehard ware alarms, underrange and overrange. | |
Display: | High Con trast, 2 line, al pha nu meric LCD with | |
| ature. |
|
Power Sup ply Re quired: | 24 to 40 VDC loop power, min i mum 11 volts re quired at in puts. | |
ReversePolarityProtection: | Yes |
|
Turn On Time: | 4 sec onds (max i mum). |
|
TemperatureLimits: | Stor age: | |
Overpressure Limits: | Proof Pres sure: 10 PSID (0.7 Bar) | Burst Pres sure: 50 PSID (3.45 Bar) |
| Max Line Pres sure: 50 PSIG (3.45 Bar). |
|
Damping: | Stan dard Time Con stant: 500 mSec. Ad di tional damp ing ad just able via in te gral key pad | |
| from 0.5 to 5 Sec onds in 0.5 sec ond in cre ments. | |
HumidityLimits: | 100% |
|
Inputs: | Standard: | |
| Op tional |
&
&ExternalAbsolutePressure:
Op tional Dig i tal In put: One op tional dig i tal (TTL level) in put is avail able.
PERFORMANCE SPECIFICATIONS
Accuracy: | For spans from 40% to 100% of max i mum range with TD of 1:1 to 2.5:1 then ac cu racy = |
| 0.15% of |
| For spans from 20% to 39% of max i mum range with TD of 2.5:1 to 5:1 then accuracy= |
| (0.15 + 0.005 X TD)% of |
| For spans from 10% to 19% of max i mum range with TD of 5:1 to 10:1 then ac cu racy = |
| (0.15 + 0.010 X TD)% of |
& | TD = Max i mum Range / |
Stability: | 0.1% of Max i mum Range / 12 Months |
AmbientTemperature: | Zero: No Ef fect Span: Less than 0.001% of |
| ternaltemperaturesensor. |
MountingPositionEffect: | Mi nor ef fect on Zero. Cor rected by setup pa ram e ters. |
VibrationEffect: | Less than 0.2% of Max i mum Range / g, |
PHYSICAL SPECIFICATIONS:
En clo sure Types: | MST2100: NEMA 1, An od ized Alu mi num. | MST2400: NEMA 4X, Fi ber glass. |
ProcessConnections: | MST2100: 1/8” NPTF | MST2400: 1/4” NPTF Stain less Steel |
ElectricalConnections: | MST2100 & MST2400: Cage Clamp style ter mi nal block. | |
| MST2400: ½” Liq | |
Weight: | MST2100: 2.5 . (1.14 kg) | MST2400: 8.0 lbs. (3.63 kg) |
Page 6 | MST2000 Multivariable SMARTFLOW ® Transmitter | Brandt Instruments, Inc. |