TANDBERG PrecisionHD 1080p/720p camera

Camera User Guide

Contentsontents

IntroductionIntroduction

PhysicalPhysicaliinterfacet rf

Cablesables

ConnectiConnect toto codec

Videoideo forformatsats

Daisyaisy chainingchaining

AppendicesApp dicesices

Contactontact usus

The VISCA™/RS–232 control protocol, cont...

Network and interface commands

Command set

Command packet

Comments

IF_Clear

8x

01 00 01 ff

Clear command buffer. Stop any

 

 

 

current operation in progress. Does not

 

 

 

do much on Rover.

Address_Set

8x

30 0p ff

p = address for this device. If x=8

 

 

 

(broadcast), increase p with 1 before

 

 

 

sending to chain.

Command_

8x

2p ff

p = Socket ID. Rover does not support

Cancel

 

 

multiple sockets. Commands will

 

 

 

always run to completion. Don’t use it

Push messages

Messages sent from camera to controller.

Command set

Command packet

Reply and comments

Network_

y0 38 ff

This indicates that cameras have been added

Change

 

to or removed from the chain.

 

 

It is recommended to wait 9 seconds after

 

 

receiving this message before doing a full

 

 

reconfigure.

IR_Push

y0 07 7d 02 gg hh ff

If IR mode is on, IR codes received by the

 

 

camera will be sent to the controller.

 

 

gg = IR ID

 

 

hh = keycode

D14640.01—MARCH 2010

22

www.tandberg.com

Page 22
Image 22