Control connections
The pinouts of the CONTROL I/O (PARALLEL) terminal on the rear panel (see “Rear panel” on page 10) are:
Pin | Function | IN/OUT |
1 | GND | — |
|
|
|
2 | Play/Flash 1 | In |
|
|
|
3 | Stop/Flash 2 | In |
|
|
|
4 | Record/Flash 3 | In |
|
|
|
5 | ≤ (Next)/Flash 4 | In |
|
|
|
6 | µ (Previous)/Flash 5 | In |
|
|
|
7 | Flash Load | In |
|
|
|
8 | Fader Start | In |
|
|
|
9 | Flash Tally | Out |
|
|
|
10 | Ready Tally | Out |
|
|
|
11 | Record Tally | Out |
|
|
|
12 | Stop Tally | Out |
|
|
|
13 | Play Tally | Out |
|
|
|
14 | Remote Select*2 | In |
15 | Ready/Flash 6 | In |
|
|
|
16 | Call/Flash 7 | In |
|
|
|
17 | Auto Cue/Flash 8 | In |
|
|
|
18 | Auto Ready/Flash 9 | In |
|
|
|
19 | Pitch/Flash 10 | In |
|
|
|
20 | Flash Page*3 | In |
21 | EOM Tally | Out |
|
|
|
22 | CF Tally | Out |
|
|
|
23 | — | — |
|
|
|
24 | — | — |
|
|
|
25 | +5V*1 | — |
In: External command reception active flow (operates at 30 ms or longer of ground)
Out: transport status by open collector
Indication signal (maximum voltage 15 V, maximum current 50 mA)
*1 Maximum supplied current is 50 mA.
*2 Pin 14 (Remote Select)
When this pin is high, the input pins for which the above table lists two commands separated by a “/” (pins
When this pin is low, the
*3 Pin 20 (Flash Page)
When pin 14 (Remote Select) is low, the assigned tracks will be as follows according to the high/low state of pin 20.
#14 | #20 | |
Low | High | |
|
|
|
Low | Low | |
|
|
|
Tall signals are open collector, with a maximum current of 50 mA. Input signals are active when low (ground) for ≥ 30 ms.
A fader start/stop control should be wired according to the following schematic:
Pin 1 GND
STOPPARALLEL
|
|
|
| |
|
|
|
| |
START | Pin 8 | |||
FADER START | ||||
|
|
TASCAM