15
Model 142 Operating Procedures
Priming
Prime the machine as close as possible to the time of
first product draw.
Step 1
With a pail beneath the door spout, open the draw
valve. Fill the mix hopper with FRESH mix and allow
it to flow into the freezing cylinder. This will for ce out
any remaining sanitizing solution. When full strengt h
mix is flowing from the door s pout, close the draw
valve.
Note: Use only fresh mix when priming the freezer.
Figure 24
Step 2
When the mix has stopped bubbling down into t he
freezing cylinder, install the feed tube in the mix inlet
hole.
Figure 25
Step 3
Place the toggle switch in the AUTO position. When
the unit cycles off, the product will be ready to serve.
Step 4
Place the mix hopper cover in position.
Figure 26
Step 5
Install the splash shield under the freezer door.
Figure 27
Step 6
Slide the rear drip pan into the hole in the front panel.
Figure 28