15
Model C713 Important: To the Operator
130626
tube. Failure to follow this instruction may result in
lower product quality when normal operation is
resumed.
To resume normal operation, press the AUTO
symbol . When the unit cycles off, the product in
the freezing cylinder will be at serving viscosity. A t
this time, turn the feed over. Place the end of the
tube with the hole into the mix inlet hole. Install the
air orifice.
Wash SymbolThe WASH symbol will illuminate when it is
touched. This indicates beater motor operation. The
STANDBY or AUTO modes must be cancelled first
to activate the WASH mode.
Auto SymbolThe AUTO symbol willilluminate when it is
touched. This indicates that the refrigeration system
has been activated. In the AUTO mode, the W ASH
or STANDBY functions are automatically cancelled.
Note: An indicating light and an audible tone will
sound whenever a mode of operation has been
selected. To cancel any function, touch the k ey
again. The light and the mode of operation will shut
off.
Reset MechanismThe reset buttons are located in the back panel of
the machine. It protects the beater motor from an
overload condition. Should an overload occur, the
reset mechanism will trip. To properly reset the
freezer place the power switch in the OFF position.
Press the reset button firmly. Turn t he power switch
to the ON position. Touch the WASH symbol and
observe the freezer's performance.
WARNING: Do not use metal objects
topress the reset button.Failure to comp lyma y
result in severe personalinjury or death.
If the beater motor is turning properly, t ouch the
WASH symbol to cancel the cycle. Touch the
AUTO symbol toresume normal operation. If the
freezer shuts down again, contact your authorized
service technician.
Feed TubeThe feed tube serves two purposes. One end of the
tube has a hole and the other end does not. The air
orifice maintains overrun and allows enough mix to
enter the freezing cylinder after a draw.
Figure 6
1. Normal O peration
During normal operation, the end of the feed
tube with the hole is placed into the mix inlet
hole. Every time the draw handle is raised, new
mix and air from the hopper flow into the
freezing cylinder. This keeps the freezing
cylinder properly loaded and maintains overrun.
2. Long “No Sale” Periods
During long “No Sale” periods, the unit can be
placed into the Standby mode. This maintains
product temperatures below 40°F (4.4°C) in
both the hopper and the freezing cylinder, and
helps prevent overbeating and product
breakdown. To activate STANDBY, enter t he
access code for the Manager Menu (see
page 17.) Remove the air orifice. Lubricate the
o-rings located on the end of the feed tube
without the hole. Place that end of the tube into
the mix inlet hole.
IMPORTANT: Make sure the level of mix in
the hopper is below the mix inlet hole in the
feed tube. Failure to followthis instruction may
result in lower product quality when normal
operation is resumed.
To resume normal operation, press the AUTO
symbol . When the unit cyclesoff, t he
product in the freezing cylinder will be at
serving viscosity. At this time, turn the feed
over. Place the end of the tube with the hole
into the mix inlet hole. Install the air orifice. T he
air orifice is used to meter a certain amount of
air into the freezing cylinder.