28 Model C713Operating Procedures
140721
Step 5
Pour the sanitizing solution into the mix hopper.
Step 6
Brush the exposed sides of the hopper.
Step 7
Place the power switch in the ON position.
Step 8
Touch the WASH symbol . This will cause the
sanitizing solution in the freezing cylinder to be
agitated. Wait at least 5 minutes before proceeding
with these instructions.
Step 9
With an empty pail beneath the door spouts, raise
the prime plug.
Step 10
When a steady stream of sanitizing solution is
flowing from the prime plug opening in the bottom of
the freezer door, open the draw valve. Momentarily
open the center draw valve to sanitize the center
door spout. Draw off the remaining sanitizing
solution.
Step 11
Once the sanitizer stops flowing from the door
spout, touch the WASH symbol and close the
draw valve.
Note: Be sure your hands are clean and
sanitized before going on in t hese instructions.
Step 12
Lubricate the feed tube o-rings on the end with the
small hole on the side. Stand the feed tube in the
corner of the hopper.
Step 13
Repeat these steps for the other sid e of the
machine.
Priming
Note: Use only FRESH MIX when priming the
freezer.
Step 1
Place an empty pail beneath the door spouts. With
the prime plug in the UP position, pour 2-1/2 gallons
(9.5 liters) of FRESH mix into the mix hopper and
allow it to flow into the freezing cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
Step 3
Once a steady stream of mix starts to flow from the
prime plug opening in the bottom of the freezer door,
push the prime plug down.
Step 4
When mix stops bubbling down into the freezing
cylinder, install the end of the feed tube with the
hole in it into the mix inlet hole in the mix hopper.
Make sure the air orifice is installed in the feed tube.
Step 5
Select the AUTO symbol .
Step 6
Fill the hopper with fresh mix and place the mix
hopper cover in position.
Step 7
Repeat these steps for the other sid e of the
machine.