18 Model C713Important:To the Operator
050722
Menu Options
Touch the ARROW symbols to move up or down
through the Menu. Select a Menu option by touching
the SEL symbol. Exit the Menu program by select ing
EXIT FROM MENU or touch the CONE sym bol .
The following menu options are listed in the
Manager's Menu.

EXIT FROM MENU

RESET DRAW COUNTER

SET CLOCK

AUTO START TIME

STANDBY MODE

MIX LEVEL AUDIBLE

LOCKOUT HISTORY

SYSTEM INFORMATION

Selecting “EXIT FROM MENU” will exit the
Manager's Menu and the return the control panel
symbols to normal operation.
The SERVING COUNTER screen is used to check
or reset the number of servings dispensed from the
machine. The SERVING COUNTER will
automatically reset to zero when the machine is
brush cleaned. (See Figure 15.)
SERVINGS COUNTER
00
> Next
Figure 15
Reset the SERVING COUNTER by selecting the
SEL symbol to advance to the next screen. Select
the UP arrow symbol to move the arrow (>) to YES
and select the SEL symbol. The servings counter
will reset to zero and exit back to the Manager's
Menu. (See Figure 16.)
RESET DRAW COUNTER
YES
>NO
Figure 16
The SET CLOCK option allows the Manager to
adjust the control clock date and time. The date and
time may only be changed after the freezer has
been manually cleaned but before it has been
placed in the AUTO or STANDBY mode. The
following message will be displayed if the SET
CLOCK option is selected when the machine is not
in a brush clean state. (See Figure 17.)
SET CLOCK
12:01 7/15/2004
NO CHANGES ALLOWED
Press Any Key
Figure 17
To change the date or time, select the SET CLO CK
option in the menu. Touch the UP arrow symbol to
advance the arrow from Exit to Change, then touch
the SEL symbol to select the Change option.
(See Figure 18.)
SET CLOCK
12:01 7/15/2004
Change
>Exit
Figure 18