C713
059899-2712/9/13
RESERVED (DO NOT USE)EXTERNAL
GROUND
L2L1
TERMINAL BLOCK
BLK/WHT
INTERFACE BOARD
POWER TRANSFORMER
BLK
ORN
RED
BLU
16V
L2
EMI FILTER
LOAD
LINEL1
L1 L2
240V
WHT
NOT
CONNECTED
WHTWHT
GRN/YEL
GRN/YEL
BLK
GRN/YEL
BLK/WHT
POWER
SWITCH
DPDT
BLK ON
OFF
RED
BLU
GRN/YEL
BLK
BLK
GRN
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON
CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP
PRP
RED/BLK
ORN/WHT
NO
NC
DRAW
SWITCH
COM
RIBBON CABLE
RED
BLU RED
BLU RED
BLU
RIBBON CABLE
WHT
WHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL
WHT
BEATER
MOTOR
STARTER
COIL
WHT ORN
WHT/ORN
BLK
BLKBLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
GRN/YEL
GRN/YEL
BLK
SV CABLE SV CABLE
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2L1 T1
CONDENSER
BLOWER MOTOR
M
BLK BLK
BLK WHT
BEATER MOTOR
STARTER BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
BLK
CLR
FUSE
15A
13
J2
J3
GND
+5V
J5
1234
J6
123456
L1
7
L2
J7
1234567
31
5
J8
J9
J12
J11
12345678
J10
123456789
10
BA
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
RED
WHT/RED
ON
OFF
J11J10
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12 8
1
95
WHITE
24 VAC
COM
BLU/WHT
WHT
BLK/BLU
BEATER
MOTOR
INTERLOCK
N.O. SWITCH
USER
INTERFACE
BOARD
- 8 LEDS
- LCD SCREEN
- 9 KEYS
- BEEPER
BLACK
BLU
WHT
BLK
BLU
BLU/WHT
BLU/WHT
RED
RED (+5v)
BLK (GRD)
HOPPER
GROUND
BLUE
BLK
M
L2
L1 T1 T2
COMPRESSOR
CONTACTOR
WHT
208
L2L1
TERMINAL BLOCK
BLU/WHT
BLK
BLK
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON
CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP/WHT
PRP/WHT
GRA/BLK
RED/BLK
NO
NC
BLK
DRAW
SWITCH
COM
RED
BLU RED
BLU RED
BLU
WHTWHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COILWHT BEATER
MOTOR
STARTER
COIL
WHT ORN
WHT/ORN
BLK
BLKBLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLU/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2
L1T1
BLK
BEATER MOTOR
STARTER BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
FUSE
15A
2 4
J2
J3
GND
+5V
J5
1234
J6
123456
L1
7
L2
J7
1234567
31
5
J8
J9
J12
J11
12345678
J10
123456789
10
BA
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12 8
1
95
BLU
WHT
BLK
BLK
M
L2
L1 T1 T2
COMPRESSOR
CONTACTOR
J18
1
2
J18
1
0
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY
TOUCHING GROUNDED UNIT BEFORE
HANDLING SOLID STATE COMPONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE
CONNECTED TO PIN 1 AT EACH END.
GROUND FRAME SECURELY
BLK
9695
9695
WHT
WHT
ON
OFF
CLR (+5v)GRN (GRD)BLK BLK
BLK
BLK BLK
SV CABLE
SV CABLE
SV CABLE
SV CABLE
SV CABLE
WHT
MIX REF. SYSTEM
(DANFOSS TL3G COMPR.)
M
COMP
FAN
1410
1113
START RELAY
START CAP
BRN WHT
WHT
BRN
BRN
BRN
BRN
BRN
BRN
BLK
BLKBLK
BLU
BLU
BLU
J1
J2
ORN/WHT
YEL
RIGHT SIDE
CONTROL
LEFT SIDE
CONTROL
BLU
BLU
BLU/WHT
BLU/WHT
BLU/WHT
BLU/WHT
GEN/YEL GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
WHT
WHT
LEFT SYRUP HEATER
WHT/RED
RIGHT SYRUP HEATER
RED/BLK
WHT
OPTIONAL
OPTIONAL
AIR COOLED
CONDENSER
FAN
M
BLK BLK
WATER COOLED
* IF THE UNIT HAS THE INTEGRAL SYRUP OPTION-405, THEN THIS
JUMPER SHOULD BE INSTALLED.
1
2
3
4
T8
T1
T7
T4
T5
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
1
2
4
6BLACK
T1
CP
T2
L1
CP
L2
3
5
ORANGE INTERNAL
RED INTERNAL
YELLOW INTERNAL
BLACK INTERNAL
BLUE
T3 L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
T3 L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
BLACK
BLUE
BEATER MOTOR
CONTACTOR
A.O. SMITH BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLUE INTERNAL
BLUE
1
2
5
4
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
CS
R
LINE
RELAYRUN
CAP.
START CAP.
COMPRESSOR
TERMINAL
COVER
ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY
TO HOOK UP A COMPRESSOR USING A START AND RUN
CAPACITOR (CSR) WITH A RELAY.
WHITE
BROWN
BLACK
BROWN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHITE(120 VOLTS)
BLACK(230 VOLTS)
BLACK
BLUE
SEE FIG. 1
FIG. 1
L1
L2
WINDING PROTECTOR
(INTERNAL)
MAIN WINDING START WINDING
START RELAY
(047702-27)
START CAPACITOR
(047703)
COMPRESSOR WIRING
(MODEL TL3G W/HST)
11
10
13
12 14
BLACKBLUEBLACKT1CPT2L1CPL2BEATER MOTORCONTACTOR GE/RBC/MARATHON BEATER MOTOR WIRINGNOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2BLUET3 L3USE T3 AND L3 WHEN CPCONTACTS ARE NOT AVAILABLEJ12 OR PURPLE INTERNALT1 OR BLUE INTERNALT8 OR RED INTERNALJ9 OR BLACK INTERNAL A
145T4 OR YELLOW INTERNAL2FIG. 3
FIG. 2
SEE FIG. 3
SEE FIG. 2
SEE FIG. 3
SEE FIG. 2
CLR
BLK
BLK/BLU
BLK/BLU
BARREL LIQUID
SOLENOID
WHT
GRY/WHT
BARREL LIQUID
SOLENOID
WHT
GRY/WHT
BLK
CLCLA
A
A
A
UVC4 BOARD FUNCTION JUMPER INSTALLED INITIALLY
JP1 PINS 1 AND 2JUMPER INSTALLED - BARREL AND HOPPER TEMPERATURES ARE CHECKED DURING AUTO/STANDBY. UNIT IS LOCKED OUT IF EITHER BARREL OR HOPPER IS TOO WARM FOR A PERIOD OF TIME. LOCKOUT OCCURS WHEN BARREL OR HOPPER IS ABOVE 45F(7C) FOR MORE THAN ONE HOUR OR ABOVE 41F(5C) FOR MORE THAN FOUR HOURS. YESNO JUMPER INSTALLED - NO LOCKOUT DURING AUTO/STANDBY IF BARREL OR HOPPER IS TOO WARM FOR A PERIOD OF TIME. PINS 3 AND 4 RESERVED (DO NOT USE) NOJP2 PINS 1 AND 2DOMESTIC CONFIGURATION - JUMPER INSTALLED. HOPPER TEMPERATURE NOT DISPLAYED ON SCREEN/HEAT SYMBOL KEYS ONLY ACTIVE WHEN A LOCKOUT CONDITION HAS OCCURRED/STANDBY KEYS DISABLED. YESINTERNATIONAL CONFIGURATION - NO JUMPER INSTALLED. HOPPER TEMPERATURES DISPLAYED ON SCREEN/MANUAL HEAT CYCLE START BY SELECTING HEAT SYMBOL/STANDBY KEYS FUNCTIONAL. JP3 RESERVED (DO NOT USE) NOJP4 RESERVED (DO NOT USE) NOJP5 RESERVED (DO NOT USE) NOJP6 RESERVED (DO NOT USE) NOJP7 JUMPER INSTALLED DISABLES RESET. NORTCK RESERVED (DO NOT USE) NODBGEN RESERVED (DO NOT USE) NOLEFTINTERFACEBOARD FUNCTION JUMPER INSTALLED INITIALLY
W1 NOW2 JUMPER INSTALLED - FORCE BRUSH CLEAN STATUS. NOW3 JUMPER INSTALLED - ACTIVATES SYRUP HEATERS NO*W4 RESERVED (DO NOT USE) NOW5 RESERVED (DO NOT USE) NOW6 JUMPER INSTALLED - REDUCED MIX LOW SENSITIVITY. NO
W7 JUMPER INSTALLED - REDUCED MIX OUT SENSITIVITY. NO
J10 PINS 7 & 8JUMPER INSTALLED W/SWITCH - SELF SERVE APPLICATION ONLY. LOCKS OUT TOUCH PANEL. NEW SWITCH ACTS AS THE ON/OFF ABILITY TO ACTIVATE THE TOUCH PANEL.NOASOFT SERVE
PERSONALITY BOARD 0-6 AMP BEATER MOTOR AMPERAGE RANGE NOBSOFT SERVE
PERSONALITY BOARD 0-12 AMP BEATER MOTOR AMPERAGE RANGE YESRIGHTINTERFACEBOARD FUNCTION JUMPER INSTALLED INITIALLY
W1 RESERVED (DO NOT USE) NOW2 JUMPER INSTALLED - ENABLES 59F HOPPER TEMPERATURE CHECK. YESW3 RESERVED (DO NOT USE) NOW4 RESERVED (DO NOT USE) NOW5 RESERVED (DO NOT USE) NOW6 JUMPER INSTALLED - REDUCED MIX LOW SENSITIVITY. NO
W7 JUMPER INSTALLED - REDUCED MIX OUT SENSITIVITY. NO
ASOFT SERVE
PERSONALITY BOARD 0-6 AMP BEATER MOTOR AMPERAGE RANGE NOBSOFT SERVE
PERSONALITY BOARD 0-12 AMP BEATER MOTOR AMPERAGE RANGE YESA
B
A
B
J13
J1
J13
J1
ADDITIONAL DRAW SWITCHFOR FLAVORBURSTDRAWSWITCHC0M
PANELJACKNO
NCRED
BLKDRAWSWITCHC0M
NO
NC
ADDITIONAL DRAW SWITCHFOR FLAVORBURSTPANELJACKREDBLKGRN/YEL
GRN/YEL
WHT
BLK/BLU
WHT
M
WHT
BLK
24VAC
OPTIONAL COVER MOUNTED HOPPER AGITATOR
COM
208
BLK
BLK
SYRUP HEATER
THERMOSTA
190F OPEN
140F CLOSE
WHT WHT WHT
WHTO.T.
FIG .4
SEE FIG. 4
SEE FIG. 4
SELF-SERVICE
ENABLE
ENABLE
DISABLE
(OPTIONAL)
BLK J1
1
2
GRD
+5V
CLR
J2 J7
UNIVERSAL CONTROL PCB A.
J9
J12
J17
J15 J8
5
46
2
13
J13
J4
J16
CABLE
RED
GRN
WHT
BLK
RIBBON CABLE
RIBBON CABLE
J3
OPTIONAL REAR
MIX LEVEL LIGHTS
IN
2
14
36
58
710
9
OUT
2
14
36
58
710
9
CABLE
J19
1
2
J20
J19
1
2
J20
CABLE CABLE
CABLE
CABLE