Taylor Pool Heat Pump owner manual Solving Problems, Error, Possible Causes, Possible Solutions

Models: Pool Heat Pump

1 28
Download 28 pages 48.72 Kb
Page 24
Image 24
SOLVING PROBLEMS

SOLVING PROBLEMS

Error

 

Possible Causes

 

Possible Solutions

Unit does not run.

1.

Power is not supplied to the

1.

Make sure that the heat pump

 

heat pump.

electrical supply line breaker is

 

2.

No demand for heat.

ON.

 

3.

Anti cycle delay (5 minutes).

2.

Make sure that the

 

 

 

temperature control is set at a

 

 

 

proper level. Adjust as required.

 

 

 

3. Whenever the compressor is

 

 

 

stopped, the digital control

 

 

 

imposes a minimal time delay of

 

 

 

5 minutes before restarting it to

 

 

 

allow gases to calibrate.

The actual water

Water is not circulating in the

Check connections.

temperature increases

right direction.

 

 

when the compressor

 

 

 

 

starts.

 

 

 

 

 

 

 

 

 

The heat pump runs

1.

Water is not circulating in

1.

Check connections.

but does not generate

the right direction.

 

 

enough heat.

2.

The heat loss of the pool

2.

See “Heat Pump Sizing”

 

exceeds the heating capacity

section on page 4.

 

of the heat pump.

3.

Use a more powerful model or

 

3.

The pool size exceeds the

use more than one heat pump.

 

specified capacity of the model

 

 

 

selected.

 

 

The heater seems to

1.

Normal - water caused by

1.

No action required.

have a water leak.

condensation.

(Install a derivation drain if

 

2.

Water leak.

necessary.)

 

 

 

2.

To verify if it is a leak, you

 

 

 

need to stop the pool heat pump

 

 

 

until all the condensation has

 

 

 

disappeared. Verify if there is

 

 

 

water remaining around the

 

 

 

machine after 24 to 48 hours.

 

 

 

(See p. 18 Q2)

The defrost sensor

Normal.

No action required.

temperature decreases

 

 

 

 

when the compressor

 

 

 

 

starts.

 

 

 

 

 

 

 

The digital control

The digital display is exposed

Make shade on the display to

displays “888”.

to the sunlight.

distinguish lights that are ON

 

 

 

from those that are OFF.

Only the fan is running.

1.

Defrost mode.

1.

No action required.

 

2.

Anti cycle delay (5 minutes).

2.

No action required.

 

3.

Defective compressor.

3.

Call an authorized service

 

 

 

technician.