SOLVING PROBLEMS
Error |
| Possible Causes |
| Possible Solutions |
Unit does not run. | 1. | Power is not supplied to the | 1. | Make sure that the heat pump |
| heat pump. | electrical supply line breaker is | ||
| 2. | No demand for heat. | ON. | |
| 3. | Anti cycle delay (5 minutes). | 2. | Make sure that the |
|
|
| temperature control is set at a | |
|
|
| proper level. Adjust as required. | |
|
|
| 3. Whenever the compressor is | |
|
|
| stopped, the digital control | |
|
|
| imposes a minimal time delay of | |
|
|
| 5 minutes before restarting it to | |
|
|
| allow gases to calibrate. | |
The actual water | Water is not circulating in the | Check connections. | ||
temperature increases | right direction. |
|
| |
when the compressor |
|
|
|
|
starts. |
|
|
|
|
|
|
|
|
|
The heat pump runs | 1. | Water is not circulating in | 1. | Check connections. |
but does not generate | the right direction. |
|
| |
enough heat. | 2. | The heat loss of the pool | 2. | See “Heat Pump Sizing” |
| exceeds the heating capacity | section on page 4. | ||
| of the heat pump. | 3. | Use a more powerful model or | |
| 3. | The pool size exceeds the | use more than one heat pump. | |
| specified capacity of the model |
|
| |
| selected. |
|
| |
The heater seems to | 1. | Normal - water caused by | 1. | No action required. |
have a water leak. | condensation. | (Install a derivation drain if | ||
| 2. | Water leak. | necessary.) | |
|
|
| 2. | To verify if it is a leak, you |
|
|
| need to stop the pool heat pump | |
|
|
| until all the condensation has | |
|
|
| disappeared. Verify if there is | |
|
|
| water remaining around the | |
|
|
| machine after 24 to 48 hours. | |
|
|
| (See p. 18 Q2) | |
The defrost sensor | Normal. | No action required. | ||
temperature decreases |
|
|
|
|
when the compressor |
|
|
|
|
starts. |
|
|
|
|
|
|
| ||
The digital control | The digital display is exposed | Make shade on the display to | ||
displays “888”. | to the sunlight. | distinguish lights that are ON | ||
|
|
| from those that are OFF. | |
Only the fan is running. | 1. | Defrost mode. | 1. | No action required. |
| 2. | Anti cycle delay (5 minutes). | 2. | No action required. |
| 3. | Defective compressor. | 3. | Call an authorized service |
|
|
| technician. |