Taylor Pool Heat Pump owner manual Water Inlet And Outlet Connections

Models: Pool Heat Pump

1 28
Download 28 pages 48.72 Kb
Page 5
Image 5
WATER INLET AND OUTLET CONNECTIONS

WATER INLET AND OUTLET CONNECTIONS

For your own security, and to ensure proper operation of the unit, the water connec- tion must be performed by a qualified person as per all applicable national, provin- cial, state or local codes.

For all Eclipse (MP) models, connection pipes are 1 1/2 inches in diameter. For all Generation (CP) models, the connection pipes are 2 inches in diameter. For all the pool heaters, we recommend (obligatory for the Eclipse series) the installation of a set of valves allowing to isolate the pool heater from the filtration system when necessary. (See the drawing below.) Moreover, you have to make sure that your pool heat pump may be disconnected from the pool pipes without having to stop the water pump or without losing great quantities of water.

Front View

Water Outlet Manual background

Manual backgroundWater Inlet

aa

Set of valves

To adjust the water flow going through the pool heater, please adjust the by-pass valve (a) in the following way:

MP30 - MP50 : 3/4 opened

MP70 : 1/2 opened

All CP’s : Closed - the internal calibrated valve regulates the water flow, exception for those who have a water pump of 2hp or greater, adjust the valve to obtain the flows listed below.

If the previous settings are not respected, the pump or the pool heater may be over- charged and result in failure of your equipement.

Your water pump must provide the quantity of water indicated in the table below. These numbers must be used for each pool heat pump installed. A flow meter must be installed on the water inlet of the pool heater to know the exact water flow. Caution : many flow meters require a long distance of straight tubing on the inlet side to offer an adequate measurement.

 

Minimum

Ideal

Maximum

 

Eclipse

15 GPM(US)

20-30 GPM(US)

50

GPM(US)

 

Generation

25 GPM(US)

40-50 GPM(US)

65

GPM(US)

GMP(US) : American gallons (3,78l) per minute

5

Page 5
Image 5
Taylor Pool Heat Pump owner manual Water Inlet And Outlet Connections