Model C707 064288-33
06/14
Taylor Company
2014 Carrier Commercial Refrigeration, Inc.
c
240K

GROUND FRAME SECURELY

NOTE:
1. STATIC ELECTRICITY MAY CAUSE DAMAGE
TO SOLID STATE COMPONENTS. ELIMINATE
STATIC ELECTRICITY BY TOUCHING GROUNDED
UNIT BEFORE HANDLING SOLID STATE COM-
PONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE CON-
NECTED TO PIN 1 AT EACH END.
BLK/WHT
BLK/WHT
WHT
WHT
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
PANEL
JACK
C0M
DRAW
SWITCH NC
NO
GRN/YEL
LINE
SPINNER MOTOR WIRING
FIG. # 2
LINE FILTER
LOAD
LINE
WHT
BLK
BLK
BLK
BLK BLK
M
(SEE FIG.2)
(SEE FIG.2)
BLK BLK
GRN/YEL
BLK
2ND PANEL SPINNER
OPTIONAL
M
BLK BLK
GRN/YEL
BLK
PANEL SPINNER
OPTIONAL
M
14
12 13
10
11
COMPRESSOR WIRING
(MODEL PL35G W/HST)
START CAPACITOR
(047703)
START RELAY
(055358)
START WINDING
MAIN WINDING
WINDING PROTECTOR
(INTERNAL)
L2
L1
(DANFOSS MODEL PL35G)
(SEE FIG.1)
RELAY
START
CAP.
START 14
10
13
11 FAN
COMP.
M
MIX REF. SYSTEMOUTMIX
MIX PUMP MOTOR
RESET SWITCH
GRN/YEL
GRA/WHT
(WATER COOLED ONLY)
FIGURE 1
BLK
BLK
BLK
BLK
BLKBLK
BLK
BLK
BLK
BLK
FIGURE 1
(WATER COOLED ONLY)
GRA/WHT
GRN/YEL
MIX PUMP MOTOR
RESET SWITCH
MIX OUTMIX REF. SYSTEM
M
COMP.
FAN
11
13
10
14
START
CAP.
START
RELAY
(DANFOSS MODEL PL35G)
(SEE FIG.1)
L1
L2
WINDING PROTECTOR
(INTERNAL)
MAIN WINDING START WINDING
START RELAY
(055358)
START CAPACITOR
(047703)
COMPRESSOR WIRING
(MODEL PL35G W/HST)
11
10
13
12
14
M
PANEL SPINNER
OPTIONAL
BLK
GRN/YEL
BLK
BLK
M
2ND PANEL SPINNER
OPTIONAL
BLK
GRN/YEL
BLK
BLK
(SEE FIG.2)
(SEE FIG.2)
M
BLK
BLK
BLK BLK
BLK
WHT
LINE
LOAD
LINE FILTER
SPINNER MOTOR WIRING
FIG. # 2
LINE
GRN/YEL
NO
NC
DRAW
SWITCH
C0M
PANEL
JACK
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
WHT
WHT
BLK/WHT
BLK/WHT
BARREL LIQUID
SOLENOID
BLU
WHT
GRY/WHT
BLK

GROUND FRAME SECURELY

NOTE:
1. STATIC ELECTRICITY MAY CAUSE DAMAGE
TO SOLID STATE COMPONENTS. ELIMINATE
STATIC ELECTRICITY BY TOUCHING GROUNDED
UNIT BEFORE HANDLING SOLID STATE COM-
PONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE CON-
NECTED TO PIN 1 AT EACH END.
240K
A
A
NO
DOOR INTERLOCK
SWITCH
C0M
WIRE #11 OF
RIBBON CABLE
BLK BLK
DRAW SWITCH
BLK
BLK BLK/WHT
BTRGNDL2L1OLCOMPBTR PUMP FAN MIX
M
WHT
BLK
CABINET FAN
MIX
LOW
MIX
OUT
MIX STANDBY
MAX
MIN
MAX
MIN
MAX
MIN
MFG DATE
MIX LOW MIX OUT
MIX STANDBY WASH AUTO PUMP
DRAW PUMP
SOFTECH CONTROL
TAYLOR CO.
42002
MIX 1 BRL
PROBE
SET POINT
S.S.VISCOSITY
SHAKE TEMP.
FAN MIX 2
DIP SWITCH
UP = OFF
1-COMP 5
2-COMP 10
3-BTR 5
4-BTR 10
5-FAN 2
6-STBY DIS
7-INTERVAL
8-INTERVAL
SHK
SWITCH INTERVAL
78 TIME
OFF
OFF
ON
ON
OFF ON
OFF
ON
16
14
11
5
PRP
RED/BLK
BRN BLK
BLK
WHT
BLK
WHT
WHT
A
A
GRN/YEL
POWER / RELAY BOARDMIX HOPPERTEMP.STBY TEMP.
C
NC
NO
L1 T1
L2 T2
L3 T3
13 14
A1 A2
BTR.
RELAY
BTR.
MTR.
A1 A2
COMP.
RELAY
COMP
95
96
PROBEMIX
BLK
BLK
BLK
L3
ORN
(AIR COOLED)
CONDENSER FAN
MODEL C706
BRN
GRA/WHT WHT
WHT
M
MOTORRELAY PUMP
ORN/WHT
WHT
342
BRN
BLK
PRP
RED ORN
BLU
MOTOR
MIX PUMP
M
WHT
OVERLOAD SWITCHBEATER MOTORCUTOUTHIGH PRESS.
WHT
BRN
RED/WHT
ORN
BLK
BLK
WHT
BLK
BLK
BLK
BLK
WHT
GRN/YEL
BLK
BLK
WHT BLK
BLK
WHITE
RED/WHT
BLK
BLK/WHT
WHT
DPDTSWITCHPOWER

AA

L1
L2
L3
T1
T2
T3
1413
L2L1

A A

RELAY
COMP.
A2A1
MTR.
BTR.
RELAY
BTR.
A2A1
1413
T3L3
T2L2
T1L1
NO
NC
C
STBY TEMP. TEMP.MIX HOPPERPOWER / RELAY BOARD
GRN/YEL
A
A
WHT
WHT BLK
WHT BLK
BLK
BRN
RED/BLK
PRP
5
11
14
16
ON
OFF
ON
OFF
ON
ONOFF
OFF
TIME8
7
SWITCH INTERVAL
SHK
8-INTERVAL
7-INTERVAL
6-STBY DIS
5-FAN 2
4-BTR 10
3-BTR 5
2-COMP 10
1-COMP 5
UP = OFF
DIP SWITCH
FAN MIX 2
SHAKE TEMP.
S.S.VISCOSITY
SET POINT
PROBE
BRL
MIX 1
42002
TAYLOR CO.
SOFTECH CONTROL
PUMP
DRAW
PUMPAUTO
WASH
STANDBY
MIX
MIX OUT
MIX LOW
MFG DATE
MIN MAX MIN MAX MIN MAX
STANDBY
MIX
OUT
MIX
LOW
MIX
CABINET FAN
BLK WHT
M
MIXFANPUMPBTRCOMPOLL1 L2GNDBTR
BLK/WHTBLK BLK
DRAW SWITCH

AA

L1L2
13 14
T3
T2
T1
L3
L2
L1

A A

POWERSWITCHDPDT
WHT
BLK/WHT
BLK
RED/WHT
WHITE
BLK
BLK
WHT
BLK
BLK
GRN/YEL
WHT
BLK
BLK
BLK
BLK
WHT
BLK
BLK
ORN
RED/WHT
BRN
ORN/WHT
WHT
HIGH PRESS.CUTOUT BEATER MOTOROVERLOAD SWITCH
WHT
M
MIX PUMP
MOTOR
BLU
ORN
RED
PRP
BLK
BRN
243
WHT
ORN/WHT
RELAY PUMPMOTOR
M
WHT
WHT
GRA/WHT
BRN
MODEL C706
CONDENSER FAN
(AIR COOLED)
ORN
L3
BLK
BLK
BLK
MIX PROBE
96 95
UNDER PRIMARY SINGLE PHASING CONDITIONS
COMPRESSOR AND BEATER MOTOR PROTECTEDCOMPRESSOR AND BEATER MOTOR PROTECTED
UNDER PRIMARY SINGLE PHASING CONDITIONS
REF. LINE
2 DIFFERENTAL
(NO SHUNT)
FIG. 3
NO
4.5
=2
JMPR
13
(SEE FIG.3)
GRN/YEL
EQUIPOTENTIAL
GROUND
GRN/YEL
GRN/YEL