![](/images/new-backgrounds/1032771/3277145x1.webp)
5−Recording
Advanced recording
Fade-in and fade-out recording
At the beginning and end of recording,
1During stop or recording standby mode, set the op- eration using the following menu options on the REC
FADE IN?
The length of the fade in to the normal level can be set between 1 and 30 seconds in
FADE OUT?
The length of the fade out into complete silence can be set between 1 and 30 seconds in
The display shows Fade Out>XXs or Fade In>XXs.
2In recording standby mode, press the FADER key on the remote control.
Recording begins and the sound fades in. After the preset
3During recording, press the FADER key on the re- mote control when you wish to
4Press the STOP key and the PMA writing will begin.
NOTE
Synchronaized recording
Synchronized recording basically means that recording will begin automatically when a signal is received, and will stop when the signal ends.
Use the SYNC REC key to select the synchronization mode. The synchronization mode determines the auto- mated start and stopping of recording when a signal is received.
During stop or recording stancby mode, repeated presses of this key cycle through the
≠Sync ALL: The SYNC indicator lights up.
≠Sync 1: The unit stops when a selected track is fin- ished and the SYNC indicator flashes
≠Sync OFF: Turns Sync recording function off
After the synchronization mode is selected, the record ready mode must then be entered (you cannot reverse the order of these steps).
Starting playback of the source automatically starts re- cording on the
Sync recording
1While recording standby mode, press the SYNC REC key repeatedly to select Sync ALL or Sync 1.
2Set the signal detection threshold level. Use the SYNC LEVEL option in the REC
Rotate the MULTI JOG dial to adjust the level. The level can be set from
Press the MENU key or push the MULTI JOG dial to enter and return to recording standby mode.
3Input the source signal.
Recording begins automatically when the source signal is detected. The source signal should be high- er than the adjusted threshold level.
level | Start of recording |
S_LVL
Noise level
time
NOTE
≠After the mode is set, more than one second of signal under the adjusted threshold level is required to start recording automatically, otherwise, the unit does not begin recording even it detects the signals.