Teka CG Lux-60 4G. Al AL, CG Lux-70 4G., CG.1 3G. 1P CG Lux-60 4G. Components of a Safety System

Models: CG Lux-70 4G. CG Lux-60 4G. Al AL CG.1 3G. 1P CG Lux-60 4G.

1 34
Download 34 pages 12.6 Kb
Page 27
Image 27

Components of a Safety System

 

 

 

 

 

G

 

 

 

 

 

 

 

On all the hobs which incorporate

 

the safety

 

 

 

 

feature (models with initials AL), the gas cut-

 

 

 

 

 

of f system is comprised formed by the follo-

 

C

A

 

 

wing elements: (See drawing 26).

 

D

E

• Safety tap

 

 

B

• Safety thermocouple next to the burner

 

 

 

 

 

Thermocouple-tap connection

 

 

 

 

Dra

The thermocouple sends an electrical

signal to

 

 

 

 

the tap, detecting the presence or absence of

 

 

 

 

 

a flame at the burner. During ignition the tap

A

Safety thermocouple

 

 

must be kept pressed in for 5 to 10 seconds

 

 

until the thermocouple heats up and sends

B

Thermocouple-tap connection

 

the flame confirmation signal to the tap. If the

C

Connection to the sparking unit

flame goes out, its absence is detected by the

thermocouple and the safety tap cuts off the

D

Sparking unit

 

 

supply of gas.

E

Ceramic head

 

 

 

 

 

F

Electrode

 

 

 

 

 

 

G

Safety tap

 

 

 