![](/images/new-backgrounds/1151851/15185127x1.webp)
Gas transformation
Important!
The transformation of the appliance to use a different gas to that for which it has been sold must only be carried out by a qualified technician.
•Use a no 7 tubular spanner to the nozzles and replace them corresponding alternative nozzles. T to tighten the nozzles well so as to risk of gas leaks.
•Reposition the pan support an covers.
Information for the Technical Service: | in the | Once the gas nozzles have been repl | |
event of conversion of the | type of gas or | following instructions | must tobe foll |
| graduate the minimum settings | . | |
pressure in the appliance, the new regulation |
|
| |
label must be placed over the existing one, in |
|
| |
| Hob CG.1 4G, CG.1 3G 1P, CGC 4G y CGC 4G | ||
order to identify the new characteristics after |
|
| |
the changeover. | AI AL |
|
|
To make the transformation replace the gas nozzles and regulate the minimum settings of the taps.
The gas nozzles necessar y for each type of gas are indicated in table 1.
To replace the gas nozzlesit is necessary to
follow the following instructions:
•Remove the pan suppor ts and the top part of the burners in order to access the nozzle.
•Remove the oven or the control p their place to access the gas taps
•Light the burners at their minimum
•Use a small screw driver to rem screw on the right or centre of th the gas key (turn left for a big fl right for a small flame).
•Once the setting has been g check that the flame remains at mum setting when the control is b turned between the maximum minimum setting.
Table 1
CG
Burner |
|
| Family |
|
| |
|
| First |
| Second | Third | |
| Group a | Group c | Group e | Group H | Group E+ | Group 3+ |
Triple | ring | 290 | 290 | 290 | 135 | 135 |
| 340 | 340 | 340 | - | - | |
Triple ring 5R (SHA) | ||||||
Fast | 260 | 260 | 260 | 116 | 116 | |
Semi fast | 185 | 185 | 185 | 97 | 97 | |
Auxiliary | 145 | 145 | 145 | 72 | 72 |
Gas nozzle diameter (Ø) expressed in 1/100 mm 14