•In order to access the screw which gradua- tes the gas flow through the taps in hob CGC 4G AI AL, remove the screws that fix the cover protecting the taps to the case and lift the cover.
Others hobs
•Remove the tap controls by pulling them upwards strongly.
•Light the burners at their minimum setting.
•Use a small screw driver to remove the screw on the right or centre of the plug of the gas key (turn left for a big flame and right for a small flame).
•Once the setting has been graduated check the the flame remains at its mini- mum setting when the control is brusquely turned between the maximum and the minimum setting.
Models CG
The only intervention necessary for the trans- formation is the replacement of the gas nozz- les and their setting.
TEKA INDUSTRIAL, S.A.will not accept
responsibility for incor rect hob operation if the gas transformation and regulation of minimum burner settings are not carried out by TEKA’s official Technical Service.