Sweep Commands
C–48 WFM 601A, WFM 601E & WFM 601M User Manual
Sweep Commands
The commands in this section allow you to manipulate the sweep characteristics
of the waveform monitor.

SWEEP:TIMING <ONEL | TWOL | ONEF | TWOF>

Sets the sweep rate to one line (5 msec/div), two line (10 msec/div), one field, or
two fields for displays other than the Parade and Eye displays. This command is
equivalent to pressing the LINE/FIELD button on the Front Panel which has four
states: ONELINE, TWOLINE, ONEFIELD, and TWOFIELD. One and two field
sweep modes do not display a time/div readout.
To set the sweep rate for the Eye display and the Parade display when you are
displaying multiple channels, see SWEEP:TIMING <ONEL | ONEF>.
SWEEP:TIMING <ONEL | TWOL | ONEF | TWOF>
SWEEP[:TIMING]?
<ONEL | TWOL | ONEF | TWOF>
sweep:timing twol
sweep:timing?
:SWEEP:TIMING TWOLINE
Syntax
Arguments
Examples
Returns