Industrial Modem MIU56 User Guide

M4

 

Speaker on during dial, answer, retrain or rate change

O1

 

Enter On-line state and force communication retrain (V.22bis and V.32bis only)

O2

 

Retrain, donÕt go on-line (V.22bis & V.32bis)

O3

 

Change line speed to 4800 bps (V.32 & V.32bis)

O4

 

Change line speed to 7200 bps (V.32 & V.32bis)

O5

 

Change line speed to 9600 bps (V.32 & V.32bis)

O6

 

Change line speed to 12000 bps (V.32 & V.32bis)

O7

 

Change line speed to 14400 bps (V.32 & V.32bis)

P

 

Pulse dialling

Q0

„

Modem returns response codes

Q1

 

Modem does not return response codes

Q2

 

Modem does not return RINGING or response codes when answering

R9

 

9600 bps (locked terminal speed - no autobaud)

R14

 

14,400 bps (locked terminal speed - no autobaud)

R19

 

19,200 bps (locked terminal speed - no autobaud)

R28

 

28,800 bps (locked terminal speed - no autobaud)

R38

 

38,400 bps (locked terminal speed - no autobaud)

R57

 

57,600 bps (locked terminal speed - no autobaud)

R115

 

115,200 bps (locked terminal speed - no autobaud)

R230

 

230,400 bps (locked terminal speed - no autobaud)

Sn?

 

Display value in S Register ÔnÕ

Sn=x

 

Place ÔxÕ in S Register ÔnÕ

T

„

Tone dialling

V0

 

Numeric response codes

V1

„

Verbal response codes

W0

 

CONNECT message reports the terminal speed

W1

 

CONNECT message reports the terminal speed

W2

„

CONNECT message reports the line speed

X0

 

Basic response codes (codes 0-4,8)

X1

 

Extended response codes (codes 0-5,8,10-12,30-40,60-62)

X2

 

Extended response codes (codes 0-6,8,10-12,30-40,60-62)

X3

 

Extended response codes (codes 0-5,7,8,10-12,30-40,60-62)

X4

 

Extended response codes (codes 0-7,10-12,30-40,60-62)

X5

„

Extended response codes (codes 0-7,10-13,30-40,60-62)

X6

 

Extended response codes (codes 0-5,7-8,10-13,30-40,60-62)

Zn

 

Restore configuration profile n (n=0,1,2,3)

&B0

 

8 bit character length

&B1

 

9 bit character length

&B2

 

10 bit character length

&B3

 

11 bit character length

&B4

„

10 or 11 bit character length determined by autobaud

&C0

 

DCD signal always asserted

&C1

„

DCD signal responds to remote modem

&C2

 

DCD signal always on, pulses low on disconnect

&C3

 

DCD asserted during voice session

&D0

 

Ignore DTR

&D1

 

Return to Local command state if DTR goes low

&D2

„

Hangup & return to Local Com if DTR goes low, disable auto-answer until DTR

 

 

asserted

&D3

 

Initialise with values in &Y profile if DTR goes low

&F0

 

Restore factory defaults

MIU56Robert Way

Page 14

2/28/2003

Page 14
Image 14
Telenetics MIU56 manual Speaker on during dial, answer, retrain or rate change