#O1

 

Disconnects if terminal buffer overflows

#O2

 

Disconnects if line buffer overflows

#O3

 

Disconnects if either buffer overflows

#PIN=n

 

Pin Number where n is the pin number

#R0

 

Remote Control Mode

#V0

 

Command and S Register verifier off

#V1

„

Command and S Register verifier on

%B0

„

S0=0 setting after AT&F

%B1

 

S0=2 setting after AT&F

%C0

 

Compression disabled

%C1

 

MNP 5 compression enabled

%C2

 

V.42bis data compression enabled

%C3

„

V.42bis data compression enabled with fallback to MNP 5

%Dn

 

Set disconnect delay to n seconds (default %D0)

%E0

 

Disable auto-retrain

%E1

„

Enable auto-retrain

%E2

 

Automatic Speed Stepping

%H0

„

Use B setting for initial MNP 10 connection speed

%H1

 

Initial connection is made at 1200 bps (MNP 10)

%H2

 

Initial connection is made at 4800 bps (MNP 10)

%H3

 

Initial connection is made at 9600 bps (MNP 10)

%H9

 

Use B setting for connection but do not upshift (MNP 10)

%K0

„

CTS operates normally

%K1

 

CTS off during dial and handshake

%L0

 

Report current received signal level (-dBm)

%Ln

 

Set transmit level (n=11 to 19; -11dBm to -19dBm)

%M0

„

Mode LEDs indicate connection speed

%M1

 

Mode LEDs indicate line quality, V.42/MNP errors & flow ctrl

%N0

„

Standard Baud Rates

%N1

 

Standard to 14400 then 20800, 31200, 41600 and 62400

%N2

 

Standard to 38400 then 51200

%P0

„

CONNECT message appears before DCD asserted

%P1

 

CONNECT message appears after DCD asserted

%Q

 

Report current line quality (EQM) (0=perfect)

%R0

„

&R command determines state of CTS

%R1

 

CTS always follows RTS (not reset by &F)

%R2

 

CTS follows DTR when offline (not reset by &F)

%S0

„

DSR is not overridden

%S1

 

DSR mimics the state of DTR (not reset by &F)

%T0

„

DCD always follows state of carrier

%T1

 

DCD is always high (not reset by &F)

%U0

„

Standard error correction response codes

%U1

 

V.42 response codes when V.42 connection established

%U2

 

V.42 response codes for V.42 connections, MNP 2,4,10 compression

%W0

„

Disable welcome message

%W1

 

Send message specified by *W to remote modem after connect

\A0

 

MNP block size = 64

\A1

 

MNP block size = 128

\A2

 

MNP block size = 192

\A3

„

MNP block size = 256

\Bn

 

Send Break sequence to remote modem (default \B3)

MIU56Robert Way