Thermador PHH30DS manual Examples of possible ducting, Typical installation, Choose vent options

Models: PHH36DS PHH30DS

1 32
Download 32 pages 59.51 Kb
Page 6
Image 6
•Typical installation

Typical installation

The height from the countertop to the bottom of the hood is 24" to 30”.These hoods are not recommended to be used over indoor grills.

1.Choose vent options

The hood is designed ready to be used for vertical discharge as shown below.

Note: see also Fig. 1-3-5 for Cabinet preparation.

If desired, the hood can be converted for horizontal discharge as shown below.

Note: see also Fig. 2-3-5 for Cabinet and rear wall preparation.

DUCTING

Provide a Round Duct having a diameter of 8” see Figure 2 and Figure 3 for location on cabinet bottom.

Install a 1/2” conduit from the service panel long enough to reach the hood once it is installed. Power supply must be rated for 120 V AC, 60 Hz. 15 or 20 A.

Examples of possible ducting

Soffit

*Deflector

Lamp

Hood

 

* Charcoal

24” to 30”

filters

 

 

 

 

 

 

 

 

 

 

Round

 

 

 

 

Duct

 

Soffit

Transition

 

Soffit

Transition

 

Blower

 

 

 

 

Blower

Blower

Lamp

 

 

Lamp

 

Filter

 

Hood

 

 

 

 

Hood

Filter

 

 

 

 

Round

 

 

 

 

 

 

 

Filter

Duct

 

24” to 30”

 

24” to 30”

 

 

 

 

 

Recirculating

Vertical discharge

Horizontal discharge

*Optional accessory - Ductless recirculation kit

6

Page 6
Image 6
Thermador PHH30DS, PHH36DS Examples of possible ducting, Typical installation, Choose vent options, Ducting, Recirculating