TABLE 2. DUCTWORK INSTALLATION GUIDELINES
For safety reasons, ducting should vent directly outdoors (not into an attic, underneath the house, into the garage or into any enclosed space).
Keep duct runs as short and straight as possible.
Duct fittings (elbows and transitions) reduce air flow efficiency.
Back to back elbows and „S“ turns give very poor delivery and are not recommended. A short straight length of duct at the inlet of the remote blower gives the best delivery.
Transition to duct from the integral blower or remote duct transition as close to the downdraft as is
1st. 10" round duct 2nd. 8" round duct 3rd.
The use of flexible metal round duct should only be used when no other duct fitting exists. Limit use to short lengths and do not crush when making corners.
•After having choosen the vent option:
1.Prepare duct and conduit cut outs, see Fig.1,2,3 as needed.