IF SYSTEM IS IN LOCKOUT,

All installations and services must be performed by qualified service personnel.

 

 

IF SYSTEM IS IN LOCKOUT,

 

 

THE MODULE WILL RESET

IF THERMOSTAT

 

ITSELF AFTER 60 MINUTES

 

OR MAY BE MANUALLY

W2 CONTACTS

 

 

RESET BY INTERRUPTING

ARE CLOSED

 

 

THE POWER TO THE FURNACE

 

 

 

 

AT THE DISCONNECT OR

 

 

INTERRUPTING THE CALL FOR

 

 

HEAT AT THE THERMOSTAT.

 

 

IF THIS DOES NOT RESTART

OTHERWISE

 

THE SYSTEM, REFER TO THE

 

 

TROUBLESHOOTING SECTION

 

 

OF THIS MANUAL.

AFTER DELAY-TO-FAN-ON PERIOD

 

 

ENDS (45 SECONDS), CIRCULATING

 

 

AIR FAN IS ENERGIZED AT LOW

 

THERMOSTAT CLOSES W2

FIRE HEATING SPEED OR HIGH

 

 

CALLING FOR HIGH FIRE

FIRE IF W2 IS ENERGIZED. THE

CALL

HEATING.

(OPTIONAL) ELECTRONIC AIR

FOR

 

CLEANER AND HUMIDIFIER

HIGH

 

ARE ENERGIZED.

FIRE

 

 

 

GAS VALVE, INDUCER AND

 

 

AIR FAN ARE ENERGIZED

 

 

TO HIGH FIRE SETTINGS

NO CALL

 

 

FOR

 

WHEN THERMOSTAT HAS

HIGH FIRE

 

SATISFIED W2, CONTACTS

 

 

OPEN AND THE GAS VALVE

 

 

AND AIR FAN HIGH FIRE

 

 

SETTINGS ARE DE-ENERGIZED

 

 

AFTER 30 SECOND DELAY.

WHEN THERMOSTAT W1 IS SATISFIED,

 

 

CONTACTS OPEN AND THE GAS

 

 

VALVE IS DE-ENERGIZED. AFTER

 

 

PROOF OF FLAME LOSS, INDUCER

 

 

STARTS 5 SECOND POST PURGE

 

 

AND (OPTIONAL) HUMIDIFIER IS

 

 

DE-ENERGIZED. THE DELAY-TO-

 

 

FAN-OFF PERIOD BEGINS (120 SECONDS)

 

 

AFTER THE DELAY-TO-FAN-OFF

 

 

PERIOD ENDS, THE CIRCULATING

 

 

AIR FAN AND (OPTIONAL) ELECTRONIC

 

 

AIR CLEANER ARE DE-ENERGIZED.

 

 