Thermo Products GMD1-60N, GDM1-80N service manual Check All

Models: GMD1-60N GDM1-80N

1 44
Download 44 pages 32.82 Kb
Page 35
Image 35
CHECK ALL

All installations and services must be performed by qualified service personnel.

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK ALL

 

 

No

IS LED LIGHT

No

DOES SYSTEM RUN UNTIL

WIRING FOR

ON INTEGRATED

THERMOSTAT IS SATISFIED?

 

 

 

LOOSE

 

CONTROL FLASHING?

 

 

 

 

 

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK FOR SHORT IN

DOES BURNER SHUT OFF

No

WIRE TO THERMOSTAT

WHEN THERMOSTAT IS

 

AND CORRECT IF

SATISFIED?

 

 

NECESSARY.

 

 

 

 

 

 

IF LED FLASHES:

 

Yes

1 FLASH, THEN PAUSE SYSTEM LOCKOUT

 

 

2 FLASHES, THEN PAUSE

PRESSURE SWITCH STUCK CLOSED

 

3 FLASHES, THEN PAUSE

PRESSURE SWITCH STUCK OPEN

 

4 FLASHES, THEN PAUSE

OPEN LIMIT SWITCH OR ROLLOUT SWITCH

 

 

 

DOES THE CIRCULATING

6 FLASHES, THEN PAUSE

115 VOLT AC POWER REVERSED

AIR BLOWER TURN OFF

 

 

AFTER THERMOSTAT IS

7 FLASHES, THEN PAUSE

LOW FLAME SENSE SIGNAL

SATISFIED WITHIN

 

 

120 SECONDS?

8 FLASHES, THEN PAUSE

CHECK IGNITOR OR IMPROPER GROUNDING

 

CONTINUOUS FLASHING

FLAME HAS BEEN SENSED WHEN NO FLAME

 

(NO PAUSE)

SHOULD BE PRESENT (NO CALL FOR HEAT)

 

THE LED WILL ALSO FLASH ONCE AT POWER-UP.

Yes

CHECK COMPLETE SYSTEM OUT.

 

 

 

LED LIGHT STAYS ON CONTINUOUSLY,

 

COMPLETE FAILURE - REPLACE INTEGRATED CONTROL.

TROUBLESHOOTING COMPLETE.

 

 

34

Page 35
Image 35
Thermo Products GMD1-60N, GDM1-80N service manual Check All