Thermo Products PHCFA072DV4R OHCFA072DV4, Low= Red Med Low= Purple Med= Blue Med Hi= Yellow

Models: PHCFA072DV4R

1 55
Download 55 pages 42.07 Kb
Page 23
Image 23
OHCFA072DV4

OHCFA072DV4

ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE

 

COOLING UNIT

 

 

Recommended HTG Speed

Recommended CLG Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

24,000

 

 

Med Low

 

 

 

Low

 

 

30,000

 

 

Med Low

 

 

 

Med Low

 

 

36,000

 

 

Med Low

 

 

 

Med

 

 

42,000

 

 

Med Low

 

 

 

Med High

 

 

48,000

 

 

Med Low

 

 

 

High

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed Tap\

 

Furnace Airflow (CFM) vs. External Static pressure (in. WC.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static Pressure

0.1

0.2

0.3

 

0.4

 

0.5

0.6

0.7

 

 

Low

1018

959

917

 

857

 

794

706

638

 

 

ML

1180

1140

1075

 

1137

 

992

952

887

 

 

Med

1311

1276

1244

 

1202

 

1146

1122

1062

 

 

MH

1554

1524

1489

 

1440

 

1403

1360

1316

 

 

HIGH

1718

1688

1656

 

1620

 

1583

1554

1524

 

 

 

Furnace Motor Current Draw (Amp/Watts) vs. External Static pressure (in. WC.)

 

 

Low

1.8/141

1.9/148

2.0/154

 

2.0/160

 

2.2/168

2.2/175

2.3/181

 

 

ML

2.6/207

2.7/213

2.8/222

 

2.8/228

 

2.9/238

3.0/245

3.1/257

 

 

Med

3.4/283

3.5/293

3.6/301

 

3.7/310

 

3.8/318

3.9/326

4.0/334

 

 

MH

5.1/442

5.2/451

5.3/460

 

5.4/466

 

5.5/480

5.6/487

5.7/496

 

 

HIGH

6.8/593

6.8/603

7.0/613

 

7.1/624

 

7.2/631

7.3/642

7.9/655

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed Tap\

 

 

Temperature Rise vs. External Static pressure (in. WC.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static Pressure

0.1

0.2

0.3

 

0.4

 

0.5

0.6

0.7

 

 

Low

69

70

72

 

77

 

83

93

103

 

 

ML

56

58

61

 

64

 

66

69

74

 

 

Med

50

52

53

 

55

 

58

59

62

 

 

 

 

 

 

MH

42

43

44

 

46

 

47

48

50

 

 

 

 

 

 

HIGH

38

39

40

 

41

 

42

42

43

 

Low= Red

Med Low= Purple

Med= Blue

Med Hi= Yellow

High= Black

Table 6: Blower Motor Speed Setup

20

Page 23
Image 23