Thermo Products PHCFA072DV4R F. Limit Position And Location, G. Burner Installation, Fig-7

Models: PHCFA072DV4R

1 55
Download 55 pages 42.07 Kb
Page 17
Image 17
F. LIMIT POSITION AND LOCATION:

F. LIMIT POSITION AND LOCATION:

WARNING: The predetermined limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace these safety controls with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.

G. BURNER INSTALLATION:

NOTICE: This furnace comes with a Riello BF3 burner preinstalled from the factory. If there is a need to remove the burner prior to installation or during service, the following explains how the burner is inserted and mounted.

The oil burner is mounted on three stud mounting bolts on the mounting plate covering the opening in the front of the heat exchanger. This unit is designed with a pre-positioned chamber. There is no insertion adjustment necessary. The unit requires only the mounting of the burner. Insertion is pre-determined. The top panel is removable by taking out the four screws for easy access to the burner and the piping. Replace this panel prior to operating the furnace.

Fig-7

H. BURNER SPECIFICATIONS AND APPLICATIONS:

The BF3 Riello flame retention oil burner is the only oil burner that can be used on the OHC.

 

THERMO

 

RIELLO

MAXIMUM

SHIPPED

OIL

 

PRIDE’S

AMULETTE

BURNER

NOZZLE

NOZZLE SIZE

PUMP

FURNACE MODEL

BURNER

 

MODEL &

SIZE**

 

PRESSURE

 

SPEC NO.

 

TUBE

 

 

(PSIG)

 

 

 

LENGTH

 

 

 

OHCFA072DV4R

C8511373

380789

BF3-4.5”

0.50X60° H

0.50X60° H

145

 

 

 

 

 

 

 

Table 3: Riello burner specifications

14

Page 17
Image 17
Thermo Products PHCFA072DV4R operation manual F. Limit Position And Location, G. Burner Installation, Fig-7