CONTROL PANEL

Sensor

 

Numbers:

28 fully supervised wireless

User Codes:

8 codes, 4 digits each

Control

 

Facilities:

Integral keypad

 

PowerCode / Code-Secure(tm)

 

hand-held transmitters

 

Wireless Keypad

Display:

Single line, backlit 16-character

 

LCD and 4 LED indicators

Setting Modes: ON, HOME, Sensor Off

Sensor

Home, House & Home,

Responses:

Walk-Thru, Entry 1, Entry 2,

 

Help Silent, Fire, Emergency,

 

Alarm and Non Alarm

Siren Signals:

Continuous (intrusion / 24 hours /

 

panic); triple pulse - pause - triple

 

pulse... (fire)

Siren Timeout:

Programmable

 

(4 minutes by default)

Internal

 

Siren Output:

At least 85 dBA at 3m (10ft)

Supervision:

4-hour reporting time-window

Data Retrieval:

Status, alarm in memory, check

Compliance

EMC Emission:

with European

EN 50081-1 1992

Standards:

RFI: EN55022 1998

 

EMC Immunity: EN 50082-1 1997

 

EMC Immunity to Conducted

 

RF: EN6100-4-6 1996

 

Telephony: TBR21 1998

 

Safety: EN060950 2000

Operating

 

Frequencies:

868.95MHz

Receiver Type:

Super-heterodyne, fixed frequency

Coding:

PowerCode and / or CodeSecure(tm)

Output Power:

Maximum 10mW

Power Supply:

Plug-in transformer 230VAC,

 

50Hz /9VAC, 700mA

Current Drain:

Approx. 95mA standby, 500 mA

 

at full load and in alarm

Internal Siren

 

Current (INT):

550* mA max.

High Current /

 

Short Circuit

All outputs are protected

Protection:

(current limited)

Total Home

 

Monitor Output

 

Current:

600mA max.

Internal Siren

Output Current: 50mA max.

Backup Battery: (Provides power for at least 8 hours). Six 1.2V NiMH rechargeable AA Cells, 1300mAh. Or six 1.2V NiCad AA Cells, 650mAh

Battery Test: Once every 24 hours, and once per hour during AC power loss

Built-in Modem: 300 baud, Bell 203 protocol

Data Transfer to

Local Computer: Via RS232 serial port

Reporting

Format Options: SIA

Operating

Temp. Range: 0°C to 49°C (32°F to 120°F)

Storage

Temp. Range: –20°C to 60°C (–4°F to 140°F)

Humidity: 85% relative humidity at 30°C (86°F)