A. OIL SUPPLY: Do not allow the fuel tank to run completely empty. During the summer, keep the tank full to prevent condensation of moisture on the inside surface of the tank. If the fuel tank runs completely dry, it may be necessary to purge the lines of trapped air. Contact a qualified technician to bleed the lines and restart the burner.

OIL SUPPLY VALVE: Turn the oil supply valve off if the burner is shut down for an extended period of time.

B. INSPECTION AREAS

VESTIBULE: The furnace vestibule area or burner compartment should be inspected by removing the front door of the furnace and looking for signs of excessive heat such as discoloration of components materials damage, from rust or corrosion, soot or carbon build-up.

EXTERIOR OF FURNACE: The furnace exterior should be inspected for signs of excessive heat such as discoloration of materials and damage from rust or corrosion.

VENT PIPE: The furnace vent pipe should be inspected for signs of holes in pipe, and leakage around seams in pipe, indicated by soot or condensate streaks.

CAUTION: DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF!

WARNING: The area around the furnace should be kept free and clear of combustible liquids and material, especially papers and rags.

WARNING: NEVER burn garbage or refuse in your furnace. Never try to ignite oil by tossing burning papers or other material into your furnace.

WARNING: Thermo Pride oil furnaces are designed to burn No. 1 or No. 2 distillate fuel oil, and should be of low or ultra-low sulfur content.

CAUTION: DO NOT ATTEMPT TO START THE BURNER WHEN:

1.Excess oil has accumulated,

2.The furnace is full of vapors

3.The combustion chamber is very hot.

IF ONE OR MORE OF THESE CONDITIONS EXIST, CONTACT A QUALIFIED SERVICE PERSON.

C. STARTING THE BURNER:

1.Turn the main service switch to "OFF" position.

2.Set thermostat substantially above room temperature.

3.Open shut-off valves in oil supply line to burner.

4.Turn service switch to furnace "ON". If burner starts and runs, but stops again on lockout, it may be necessary to bleed the lines or make burner combustion air adjustments. Contact a qualified service person to adjust and start burner.

D. FILTER CLEANING AND LOCATION:

WARNING: To avoid injury from moving parts, hot surfaces, or electrical shock, shut off the power to the furnace before removing any furnace access doors to service the air filters.

31

Page 34
Image 34
Thermo Products PHCFA072DV4R B. Inspection Areas, Caution Do Not Attempt To Make Repairs Yourself, C. Starting The Burner