The entire text of these instructions must be read and understood, before installing the appliance. It is the installer's responsibility to do the following:

1.Inform and demonstrate to the user, the correct operation and maintenance of the appliance, as explained in the Homeowner/User Information and Routine Maintenance section of this manual.

2.Inform the user of the hazards of flammable liquids and vapors and to remove such liquids and vapors from the vicinity of the appliance.

3.Inform the user of all pertinent warnings and precautions concerning this appliance.

WARNING: This unit is not to be used for temporary heating of buildings, or structures, under construction. Construction dust may enter the appliance or the duct system and cause a fire hazard. Certain chemicals used during construction when burned, form corrosive condensate that can substantially reduce the life of the heating system heat exchanger.

This appliance is shipped completely assembled and internally wired. All electrical wiring has been factory installed and inspected. At the time of installation, the unit will require connection to electric power, fuel oil supply, and supply and return air ductwork. In the event of a shortage of parts or damage, contact Thermo Pride office.

This unit uses a fan-assisted combustion system, consisting of a pressure atomizing, oil burner and combustion air blower, used to push the products of combustion through the heat exchanger system. After installation, the furnace and duct system must be adjusted to obtain a temperature rise of 50°F to 80°F through the unit. (Refer to the rating label located on side panel inside the burner compartment). The installation must conform with local codes or, in the absence of local codes, with the Standard for the Installation of Oil-Burning Equipment, NFPA 31-1997, or the latest edition, and to these instructions. The installation must also comply with CSA B139 for recommended installation practices where applicable.

A. CODES AND CLEARANCES:

The following items must be considered when choosing the size and location of the unit.

1.All local codes and/or regulations take precedence over the instructions in this manual and should be followed accordingly. In the absence of local codes, installation must conform to these instructions and the guidelines of the National Fire Protection Association (NFPA). Two applicable NFPA installation codes are the National Electrical Code, ANSI/NFPA 70-1999, and Standard for the Installation of Oil-Burning Equipment, NFPA 31-1997. The latest editions of these codes should be consulted.

2.The selection of a heating unit should be based on a rate of heat loss calculation for the residence according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE). The heating capacity of the unit proposed for installation should meet or slightly exceed the rate of heat loss for the residence. Over sizing should not exceed 25% of the heat loss calculation.

3.When installed, this unit should be level. If possible, it should be installed in a central location, with respect to outlet registers of the supply air ductwork.

4.A furnace installed in a residential garage must be installed so the burner and ignition source are located higher than 18 inches above the floor. The furnace must also be located or protected to avoid physical damage by vehicles.

5.Definitions of "combustible" and "non-combustible" materials as presented in the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 70, are as follows:

3

Page 6
Image 6
Thermo Products PHCFA072DV4R operation manual Codes and Clearances

PHCFA072DV4R specifications

The Thermo Products PHCFA072DV4R is a cutting-edge heating and cooling solution designed for modern residential and light commercial applications. This unit stands out due to its efficient performance and advanced technology. One of the most remarkable features of the PHCFA072DV4R is its energy efficiency. It boasts a high SEER rating that ensures reduced energy consumption without sacrificing comfort, making it an environmentally friendly choice for homeowners.

This system utilizes an inverter-driven compressor, which allows for variable speed operation. This means that the unit can adjust its output to match the specific heating or cooling needs of a space, providing more consistent temperatures and enhanced comfort. Additionally, this inverter technology minimizes noise levels, making the PHCFA072DV4R a quieter option compared to traditional fixed-speed systems.

Another noteworthy characteristic of the PHCFA072DV4R is its advanced filtration system. It is equipped with high-efficiency filters that effectively capture dust, pollen, and other airborne particles, ensuring improved indoor air quality. For those who suffer from allergies or have respiratory issues, this feature can provide significant relief.

The unit offers a user-friendly interface with a smart thermostat that enables users to control the system remotely. Through a mobile app, homeowners can adjust settings, set schedules, and monitor energy usage from anywhere, which adds a layer of convenience to the overall user experience.

Additionally, the PHCFA072DV4R is built with durability in mind. Its robust construction and high-quality materials ensure long-term reliability, reducing the likelihood of costly repairs. It also comes with a warranty that reflects the manufacturer's confidence in the product's performance.

Overall, the Thermo Products PHCFA072DV4R encapsulates efficiency, comfort, and advanced technology in a single package. Its ability to adapt to varying conditions, combined with features focused on air quality and ease of use, make it a prime choice for anyone looking for a versatile heating and cooling solution. This unit not only meets the demands of today's consumers but also aligns with sustainable practices, making it an ideal addition to any home or business.