Thermos The Big Easy Quickset Traditional LP Gas Grill manual LP Tank Exchange, LP Tank Leak Test

Models: The Big Easy Quickset Traditional LP Gas Grill

1 32
Download 32 pages 31.92 Kb
Page 7
Image 7
Safety Relief Valve

LP Tank Exchange

Many retailers that sell grills offer you the option of replacing your empty LP tank through an exchange service. Use only those reputable exchange companies that inspect, precision fill, test and certify their cylinders. Exchange your tank only for an OPD safety feature-equipped tank as described in the "LP Tank" section of this manual.

Always keep new and exchanged LP tanks in upright position during use, transit or storage.

Leak test new and exchanged LP tanks BEFORE connecting to grill.

LP Tank Leak Test

For your safety

Leak test must be repeated each time LP tank is exchanged or refilled.

Do not smoke during leak test.

Do not use an open flame to check for gas leaks.

Grill must be leak checked outdoors in well-ventilated area, away from ignition sources such as gas fired or electrical appliances. During leak test, keep grill away from open flames or sparks.

Use a clean paint brush and 50/50 soap and water solution. Use mild

soap and water. Do not use household cleaning agents. Damage

to gas train components can result.

Brush soapy solution onto the shaded areas.

If "growing" bubbles appear do not use or move the LP tank. Contact an LP gas supplier or your fire department!

Connecting Regulator To The LP Tank

1.LP tank must be properly secured onto grill. (Refer to Assembly Manual)

2.Turn all control knobs including sideburner (if featured) to the OFF position.

3.Turn LP tank OFF by turning hand- wheel clockwise to a full stop.

4.Remove the protective cap from LP tank valve. Always use cap and strap supplied with valve.

O

Clockwise

ff

 

Strap and Cap

OPD Hand

Wheel

Type 1 outlet with thread on outside

7

Page 7
Image 7
Thermos The Big Easy Quickset Traditional LP Gas Grill manual LP Tank Exchange, LP Tank Leak Test, For your safety