Supply Requirements

Electrical power supply

UNIT

RATING

SUPPLY

 

 

 

Machine (CNC)

200V~220 VAC 3 phase 60 Hz (15 Amp, 12 KVA)

200~220 VAC 3 phase**

 

 

 

Laser

Fanuc AF4000 4kW CO2 Fast Axial Flow:

200~220 VAC 3 phase**

 

200V~220 VAC 3 phase 60 Hz (160 Amp, 55 KVA)

 

 

 

 

Chiller

Orion RKL-15000:

200~220 VAC 3 phase**

 

200 VAC 3 phase ￿10% 60 Hz (97 Amp, 36 KVA)

 

 

 

 

Total @ 200-220

125 KVA

200~220 VAC 3 phase**

 

 

 

Beam purge unit

Orion QSP180-11CA : 115V 1ph ￿10% 50/60 Hz (23W)

 

 

 

Dust collector 3

Torit DFT3-18: 460 VAC* 3 phase ￿10% 60 Hz (18 KVA) 15 hp

 

Farr GS-12: 460 VAC* 3 phase ￿10% 60 Hz (20 KVA)

 

 

 

* Units at other than 208 V not included in transformer sizing.

** This is a min-max specification: no additional ￿ applies.

3Contact Amada to determine which dust collector is provided.

6

LC3015 Theta User Installation Guide - October, 2003

Page 14
Image 14
Theta Digital LC3015-2 manual Supply Requirements