Air specifications - ISO 8573.1 standard

The standard provides a uniform way to specify air quality in terms of particle size, pressure dewpoint, and oil content.

Class 2-4-3 means class 2 particulate, class 4 dewpoint, and class 3 oil content. (1 micron particulate, 37 ￿F dewpoint, 1 mg/m3 oil content) (maximums)

The following table lists the maximum contaminations in each category.

Quality Class

Particle size in microns

Pressure dewpoint

Oil content

 

 

 

 

1

0.1

–70 ￿c (–57￿F)

0.01 mg/m3

2

1

–40 ￿c (–40￿F)

0.1 mg/m3

3

5

–20 ￿c (–4￿F)

1 mg/m3

4

15

+3 ￿c (37￿F)

5 mg/m3

5

40

+7 ￿c (45￿F)

25 mg/m3

 

 

 

 

Connections

The customer must provide:

Hose, regulator, and fittings for the dust collector.

Hose and fittings for the machine.

Laser pre-mixed gas (see page 9)

Assist gas (oxygen minimum) (see page 10)