Assembly Section 5-5

TRIPLE EGRESS TROUBLESHOOTING

FAILURE MODE: CHECK STEPS
- DECK OR DRAFT CYLINDER ONL Y GOES ONE W A Y. 1 and 2
- DECK OR DRAFT CYLINDER WILL NOT ST A Y IN POSITION. 1 and 2
- WILL OPERA TE WITH LIFT V AL VE, BUT NOT WITH EGRESS. 3 and 5
- EGRESS DOES NOT OPERATE AS FAST AS IT USED T O. 3 and 4
CORRECTIVE STEPS:
1. Remove relief valve installed on tractor lift valve. Visually inspect for contamination.
2. Remove solenoid valve (S1, S2, S3, S4) from egress unit and verify spool shift.
3. Remove relief valve from egress unit and visually inpect for contamination.
4. Inspect suction strainer for contamination.
5a. V erify supply voltage at pump motor posts on egress.
5b. V erify voltage at pump motor relay while switches are activated.
5c. V erify voltage at solenoid valve (S1, S2, S3, S4) on egress unit.
5d. Check or reset curcuit breaker .
NOTE:
1. All voltage readings must be between 10.2 volts and 13.8 volts.
7-25-02