Tiger Products Co., Ltd JD 72-7520 manual Load Sense Line Installation, Assembly, End Cap Update

Models: JD 72-7520

1 144
Download 144 pages 29.2 Kb
Page 32
Image 32
LOAD SENSE LINE INSTALLATION

ASSEMBLY

LOAD SENSE LINE INSTALLATION

To install the load sense lines from a Husco valve to the tractor remote valve, first the existing load sense line located on the top of the tractor remote valve connecting “load sense -1” and “load sense -2” must be removed, in order so that the two load sense lines are able to be connected to the Husco valve. Next connect a 1/4” hose (load sense - 1) to the tractor remote valve and to the top front port on the Husco valve. Next connect a 1/4” (load sense - 2) to the tractor remote valve and to the port to the lower right of the “load sense-1” line on the Husco valve.

For more information refer to the Parts Section pages for a complete diagram of the tractor valve hookup.

2004 END CAP UPDATE

PRESSURE LINE INSTALLATION

The hydraulic pressure line will be plumbed into the rear of the tractor remote valve end cap. Locate the pressure port on the end cap and remove the plug (refer to the illustration below and the Parts Section pages for position of the pressure port). After the plug is removed then install 22mm adapter. Next connect a 1/2” hose from the tractor remote valve to the Tiger valve.

RETURN LINE INSTALLATION

The return line will be plumed in next to the pressure line in the tractor remote valve end cap. Locate the return port and remove the plug (refer to the illustration below and the Parts Section for the position of the return port). After the plug is removed then install 22mm adapter or elbow. Next connect a 1/2” hose from the tractor remote valve to the Tiger valve.

END CAP

PRESSURE RETURN LOAD SENSE

Assembly Section 2-8

Page 32
Image 32
Tiger Products Co., Ltd JD 72-7520 Load Sense Line Installation, Assembly, Pressure Line Installation, End Cap Update