5.2 Fault in Specific Station Only

Find the cause according to the following table if the fault lies with a specific station only, not with all stations.

SYMPTOM

Dialing can not be made at privacy off mode.

Specific key does not operate.

Calling tone can not be heard. Sound from the other party can not be heard.

Sound is not trans- mitted to the other party.

On dialing, noise is heard by the called party.

Sound of the other party is broken during call.

Immediately after the calling tone, the line switches to cancel, busy, dial tone, etc.

CHECK-ITEM

 

CAUSE

Replace the

*

Disconnection of both T & R Lines.

station and make

* T & R Lines are shorted.

sure that the

 

 

station is not

 

 

faulty.

 

 

Replace the

*

Fault in key board switch or matrix circuitry.

station and make

*

Fault in the dial generator. (Replace PCB

sure that the

 

board.)

station is not

 

 

faulty.

 

 

Same symptom

*

Short or open in R Line.

remains even if

*

Fault in LAU.

the station is

 

 

replaced.

 

 

Becomes normal

*

Disconnection of R Line or improper connec-

if the station is

 

tion of the station connector.

replaced.

*

Fault in LAU.

 

*

Station fault.

Same symptom

*

Short or open in T Line.

remains even if

*

Fault in LAU.

the station is

 

 

replaced.

 

 

Becomes normal

*

Fault in MIC circuitry of the station. (Replace

if the station is

 

MIC or PCB.)

replaced.

 

 

Same symptom

*

One of T Lines is disconnected.

remains even if

*

Fault in LAU.

the station is

 

 

replaced.

 

 

Becomes normal

*

Fault in MIC element.

if the station is

*

Fault in T Line of the station.

replaced.

*

Low-frequency oscillation of MIC AMP.

 

 

(Faulty bypass capacitor.)

Same symptom

* Adjust the volume control of station speaker

remains even if

 

if the room produces reverberation. (Lower

the station is

 

the volume.)

replaced.

*

Increase the gain of MIC AMP.

 

*

Replace PCB after checking if MIC unit is not

 

 

touching its case.

Same symptom

* One of R Lines is disconnected.

remains even if

*

Fault in LAU.

the station is

*

Station fault.

replaced.

 

 

Becomes normal

*

One of the R Lines is disconnected or the

if the station is

 

station connector is not connected properly.

replaced.

 

 