TOA Electronics EX-16 manual Inspect Before Turning Power On, Function Selection

Models: EX-16

1 36
Download 36 pages 18.9 Kb
Page 27
Image 27

4.Installation Adjustment

4.1Inspect Before Turning Power On.

*Before supply power, check the power connections (power connections should be complete) and the fuse. Also, voltage selector should be set correctly. All modules should be in place.

Check the ROM on the CPU-16. It should be set securely in the socket. Make sure that exchange and stations are properly connected.

*Turn power on.

*AC indicator lamp on the DSM-16 should go on. If not, electricity is not on. Turn off power and check the connections and fuses.

*Handle plug-in units with care; plug-in units incorporate CMOS. After the exchange is turned on, do not attempt to disconnect the plug-in units.

4.2Function Selection

Select door remote or power remote, as shown in the following diagram, using the program switch on the CPU-16.

CPU-16 P.C.B.

Program Switch

25

Page 27
Image 27
TOA Electronics EX-16 manual Inspect Before Turning Power On, Function Selection