3.8.1BGM Input
Input impedance: 50 K (unbalanced)
Input level: |
Output level: 100mW
(a)Remove the short bar connected to the terminal.
(When BGM is not employed, the short bar should be kept on the terminal. If the short bar is not replaced, a humming sound will be heard from the station.) The short bar is referred to on page 3.
(b)Connect the BGM equipment. (Be sure to use the type of BGM equipment which meets the input specifications. Since the level adjustment cannot be controlled in the exchange, the BGM equipment must have an output level adjuster.)
(c)After installation, adjust the output level of the BGM through the speaker. If the input is excessive, there will be distortion.
3.8.2 All-Call Paging Output
Output | impedance: | 600 (unbalanced) |
Output | level: | 0dBm |
(a)Connect a paging amp which matches the output specifications.
(b)Test the paging output level and adjust to eliminate feedback. (Placing the speaker too close to the station sometimes causes feedback.)
3.8.3 Remote Control Output |
|
|
|
Output signal: | no voltage contact |
| |
Contact capacity: | 125VA |
|
|
The program switch on the | |||
following 2 functions for remote control. |
|
| |
1. Door Remote Control |
|
|
|
Every master station can be used as a remote control device for the door | |||
opening function. Pressing buttons | and | allows a | |
wherein the door can be opened. |
|
| |
2. Power On/Off Remote Control |
|
|
When the system is used in conjunction with a PA amplifier for the external
by pressing
19