Troubleshooting
10 Troubleshooting
Symptom |
| Possible cause | Solution |
|
|
|
|
No display |
| Batteries uncharged | Check the position of the |
|
|
| batteries |
|
|
|
|
|
|
| Recharge the batteries |
|
| Handset turned off | Turn on the handset |
No tone |
| Telephone cord badly connected | Check the telephone cord |
|
|
| connection |
|
|
|
|
|
| The line is occupied by another | Wait until the other handset |
|
| handset | hangs up |
|
|
|
|
The icon | flashes | Handset out of range | Bring the handset closer to the |
|
|
| base |
|
|
|
|
|
| The base has no power supply | Check the mains connection |
|
|
| to the base |
|
|
|
|
|
| The handset is not registered on | Register the handset on the |
|
| the base | base |
|
|
| |
Base or handset do not ring | The ringing volume is off or low | Adjust the ringing volume | |
Tone is good, but there is no | The dialing mode is wrong | Adjust the dialing mode | |
communication |
| (pulse/tone) | |
|
|
| |
Not possible to transfer a call | The flash time is too short or too | Change the flash time | |
on PABX |
| long |
|
|
|
| |
Telephone does not react | Manipulation error | Remove the batteries and put | |
when pressing the keys |
| them back in place | |
|
|
|
|
11 Technical dataTechnical characteristics
Standard | DECT (Digital Enhanced Cordless Telecommunications) |
| GAP (Generic Access Profile) |
Frequency range | 1880 MHz to 1900 MHz |
Number of channels | 120 duplex channels |
Modulation | GFSK |
Speech coding | 32 kbit/s |
Emission power | 10 mW (average power per channel) |
Range | maximum 300m in open space / |
Number of handsets | Up to 5 |
Base power supply | 230V / 50 Hz / 7,5V DC 300mA |
Handset Batteries | 2 rechargeable batteries AAA, NiMh 1,2V, 550mAh |
Handset autonomy | 200 hours in standby |
Handset talk time | 10 hours |
Normal conditions of use | +5 °C to +45 °C |
Dialing mode | Pulse / Tone |
Flash time | 100 or 250 ms |
24