| OGATECH |
|
|
|
|
|
The icon |
| flashes | Handset out of range | Bring the handset closer to |
| ||||
|
|
|
| the base |
|
|
| The base has no power sup- | Check the mains connection |
|
|
| ply | to the base |
|
|
| The handset is not registered | Register the handset on the |
|
|
| on the base | base |
|
|
|
|
|
Base or handset do not ring | The ringing volume is zero or | Adjust the ringing volume | ||
|
|
| low |
|
|
|
|
|
|
Not possible to transfer a call | The FLASH time is too short | Set the unit to Long Flash | ||
on PABX |
| time | ||
|
|
|
|
|
Telephone does not react to | Manipulation error | Remove the batteries and put | ||
pressing the keys |
| them back in place | ||
|
|
|
|
|
12TECHNICAL DATA
• | Standard: | DECT (Digital Enhanced Cordless Telecommunications) |
|
| GAP (Generic Access Profile) |
• | Frequency range: | 1880 MHZ to 1900 MHz |
• | Number of channels: | 120 duplex channels |
• | Modulation: | GFSK |
• | Speech coding: | 32 kbit/s |
• | Emission power: | 10 mW (average power per channel) |
• | Range: | 300 m in open space /50 m maximum inhouse |
• | Numbr of handsets: | Up to 5 |
• | Powersupply base | 230V / 50 Hz / 35 mA 6,5V DC 180mA & 150mA |
• | Handset Batteries: | 2 rechargeable batteries AAA, NiMh 750mAh 1,2V |
• | Handset autonomy: | 100 hours in standby |
• | Talk time: | 10 hours |
• | Charging time: | |
• Normal conditions of use: | +5 °C to +45 °C | |
• | Flash time | 100 or 250 ms |
13DEFAULT SETTINGS
• | Handset name: | |
• | Auto talk: | ON |
• | PABX code | Empty (Off) |
•Handset ring volume: 3
• | Ear volume: | 3 |
• | Melody Handset: | Internal calls = 1 and external = 5 |
• | Menu color: | Blue |
• | Base ring volume: | 3 |
• | Base ringtone: | 1 |
• | Pin code: | 0000 |
• | Key lock: | Off |
• | SMS melody: | On = Morse |
ENGLISH