Set Temperature Activation Threshold (TWRFS models only)
The freeze sensor temperature activation threshold is adjustable from 35°F to 45°F or 2°C to 7°C. When the air temperature reaches the threshold setting, the freeze sensor activates the receiver. The Freeze Sensor Status indicator will turn on. The sensor system will return to the Monitor mode when the outside air temperature rises above the sensor threshold temperature.
Select Temperature Threshold
1.Press the Setup button to display Freeze. The display will indicate the current temperature threshold setting. See Figure 16.
Note: The display prompt will begin flashing to indicate the selected feature is adjustable.
2.Press the Adjust button to select the preferred temperature.
Select Temperature Scale
1.Press the Setup button to display °F or °C. The display will indicate the current temperature scale.
2.Press the Adjust button to display the alternate scale.
Congratulations!
Figure 16 |
Figure 17 |
Your Wireless RainSensor system installation is complete. Now, to take advantage of the unique Water Conservation feature, review the information on the next page and select the level that best suits your landscape application.