GENERAL ADJUSTMENTS

CHAPTER 2 SPECIFIC INFORMATIONS

SETTING & ADJUSTING DATA

SAFETY INSTRUCTIONS

 

 

36"

HIGH VOLTAGE AT ZERO BEAM:

(A)

32.7 kV

MAX HIGH VOLTAGE:

(B)

34.1 kV

Table-1

SERVICE MODE

ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:

SPECIFIC INFORMATIONS

Item

Name of adjustment

Preset

Data

 

 

 

 

RCUT

R CUTOFF

40H

GCUT

G CUTOFF

40H

BCUT

B CUTOFF

40H

GDRV

G DRIVE

40H

BDRV

B DRIVE

40H

BRTC

BRIGHT CENT

80H

TNTC

TINT CENT

46H

SCOL

SUB-COLOR

06H

SCNT

SUB-CONTRAST

12H

HIT

HEIGHT

40H

LIN

V-LINEARITY

14H

VSC

V-S CORRECTION

36H

VPS2

V-SHIFT

02H

VCP

V-COMPENSATION

02H

WID

PICTURE WIDTH

1EH

 

 

 

 

Item

Name of adjustment

Preset

Data

 

 

 

 

PARA

E-W PARABOLA

16H

CNR

E-W CORNER

13H

TRAP

TRAPEZIUM

33H

HCP

H-CONMPENSATION

02H

VFC

V-F CORRECTION

0CH

HPS

H-POSITION

3FH

GMPS

GMPS

2FH

CPAR

CENTER PARA

04H

PHUE

PIP TINT

40H

PCNT

PIP CONTRAST

0FH

PCOL

PIP COLOR

19H

PYOF

PIP Y OFF SET

17H

PIOF

PIP I OFF SET

24H

PQOF

PIP Q OFF SET

1EH

 

 

 

 

 

 

 

 

 

 

 

Table-2

 

 

 

OPTION: (PROGRESSIVE 4:3 DV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODELS

OPT1 (2CAH)

OPT2(2CBH)

 

 

 

 

HEX

 

HEX

 

 

 

 

 

 

 

 

 

36"

 

4AH

 

25H

 

 

 

 

 

 

 

Table-3

 

 

 

 

CIRCUIT CHECKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAIL SAFE DET. VOLTAGE

(C)

20.44 V

 

 

 

 

 

 

 

 

 

 

 

 

Table-4

– 14 –

Page 16
Image 16
Toshiba 32HFX72 Specific Informations Setting & Adjusting Data, Safety Instructions, Option Progressive 43 DV